Lexmark c912 Guía De Referencia

Descargar
Página de 459
Interfaces
8-41
 
Serial Communication Parameters (RS-422)
The following paragraphs show acceptable values for serial communication 
parameters.
Voltage Level
RS-422 serial interface uses a differential pair, 5-volt typical delta, 0.5 volt threshold. 
Your printer uses a TI75179 transceiver with transorbs. The polarity of the signals is 
programmable.
Serial Data Frame Considerations
The computer sends serial data in data frames (also known as packets). You can 
create 10-bit, 11-bit, or 12-bit data frames and set the serial data transfer parameter 
so that each data frame contains 7 or 8 data bits. However, your printer is an 8-bit 
printer; characters, controls, and APA graphics need 8 bits of data. If you select 7-bit 
data transfer, some unexpected characters might print.
Data Transmission
The list of acceptable data transfer rates (in bits per second) can be accessed from 
your printer operator panel or through MarkVision Professional. Refer to your printer 
user documentation for more information.
Data Bits
Your printer sends or receives 7 or 8 data bits in each transmission frame, depending 
on which one is selected.
Start and Stop Bits
Your printer receives data with 1 start bit and either 1 or 2 stop bits. The printer always 
sends 1 start and 2 stop bits.