PRODUCT DATA SHEETS
Base Grille Water Filtration System
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The 
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the 
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Model WF-NL240V/NL240V Capacity 240 Gallons (908 Liters)
Model WF-L400V/L400V Capacity 400 Gallons (1514 Liters)
It is essential that operational, maintenance, and filter 
replacement requirements be carried out for the product to 
perform as advertised.
Model WF-NL240V: Change cartridge at least every 6 months. 
Use replacement cartridge NL240V, part #4396509. 2008 
suggested retail price of $35.99 U.S.A./$59.95 Canada. Prices 
are subject to change without notice.
Model WF-L400V: The filter monitor system measures the 
amount of water that passes through the filter and alerts you 
to replace the filter. When 90% of the filter’s rated life is used, 
the filter indicator light changes from green to yellow. When 
100% of the filter’s rated life is used, the filter indicator light 
changes from yellow to red, and it is recommended that you 
replace the filter. Use replacement cartridge L400V, part 
#4396509. 2008 suggested retail price of $35.99 U.S.A./
$59.95 Canada. Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of 
unknown quality without adequate disinfection before or after the 
system. 
Refer to the front cover or “Assistance or Service” section for the 
Manufacturer’s name, address and telephone number.
Refer to the “Warranty” section for the Manufacturer’s limited 
warranty.
 
System tested and certified by NSF International against NSF/ANSI 
Standard 42 for the reduction of Chlorine Taste and Odor, Particulate 
Class II*; and against NSF/ANSI Standard 53 for the reduction of Lead, 
Mercury, Benzene, Toxaphene, p-dichlorobenzene, and Carbofuran.
Substance Reduction
Aesthetic Effects
NSF Reduction 
Requirements
Average
Influent
Influent Challenge 
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average % 
Reduction
Chlorine Taste/Odor
Particulate Class II
*
50%
85%
1.94 mg/L
833,333/mL
2.0 mg/L ± 10% At least 
10,000 particles/ml
0.05 mg/L
100,000/mL**
0.05 mg/L
40,667/mL
97.4%
88.0%
97.4%
95.1%
Contaminant
Reduction
NSF Reduction 
Requirements
Average
Influent
Influent Challenge 
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average % 
Reduction
Lead: @ pH 6.5
Lead: @ pH 8.5
0.01 mg/L
0.01 mg/L
0.15 mg/L***
0.148 mg/L***
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.001 mg/L
0.003 mg/L
0.001 mg/L
0.001 mg/L
99.3%
97.9%
99.3%
99.0%
Mercury: @ pH 6.5
Mercury: @ pH 8.5
0.002 mg/L
0.002 mg/L
0.006 mg/L
0.0061 mg/L
0.006 mg/L ± 10%
0.006 mg/L ± 10%
0.0002 mg/L
0.0009 mg/L
0.0002 mg/L
0.00052 mg/L
96.60%
85.2%
96.6%
91.8%
Benzene
0.005 mg/L
0.014 mg/L
0.015 ± 10%
0.0005 mg/L
0.0005 mg/L
96.06%
96.06%
p-dichlorobenzene
0.075 mg/L
0.235 mg/L
0.225 ± 10%
0.0019 mg/L
0.0009 mg/L
99.1%
99.6%
Toxaphene
0.003 mg/L
0.014 mg/L
0.015 ± 10%
0.0012 mg/L
0.001 mg/L
92.7%
92.6%
Carbofuran
0.04 mg/L
0.077 mg/L
0.080 ± 10%
0.031 mg/L
0.0064 mg/L
61.03%
91.94%
Substance Reduction
Aesthetic Effects
NSF Reduction 
Requirement
Average
Influent
Influent Challenge 
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average % 
Reduction
Chlorine Taste/Odor
Particulate Class II
*
50%
85%
1.94 mg/L
833,333/mL
2.0 mg/L ± 10% At least 
10,000 particles/ml
0.05 mg/L
100,000/mL**
0.05 mg/L
40,667/mL
97.4%
88.0%
97.4%
95.1%
Contaminant
Reduction
NSF Reduction 
Requirement
Average
Influent
Influent Challenge 
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average % 
Reduction
Lead: @ pH 6.5
Lead: @ pH 8.5
0.01 mg/L
0.01 mg/L
0.15 mg/L***
0.148 mg/L***
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.001 mg/L
0.003 mg/L
0.001 mg/L
0.0014 mg/L
99.3%
97.9%
99.3%
99.3%
Mercury: @ pH 6.5
Mercury: @ pH 8.5
0.002 mg/L
0.002 mg/L
0.0061 mg/L
0.0061 mg/L
0.006 mg/L ± 10%
0.006 mg/L ± 10%
0.0002 mg/L
0.0009 mg/L
0.0002 mg/L
0.00052 mg/L
96.60%
85.2%
96.6%
91.8%
Benzene
0.005 mg/L
0.014 mg/L
0.015 ± 10%
0.0005 mg/L
0.0005 mg/L
96.06%
96.06%
p-dichlorobenzene
0.075 mg/L
0.235 mg/L
0.225 ± 10%
0.0019 mg/L
0.0009 mg/L
99.1%
99.6%
Toxaphene
0.003 mg/L
0.014 mg/L
0.015 ± 10%
0.0012 mg/L
0.001 mg/L
92.7%
92.6%
Carbofuran
0.04 mg/L
0.077 mg/L
0.080 ± 10%
0.031 mg/L
0.0064 mg/L
61.03%
91.94%
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 gpm (1.9 L/min.) @ 60 psi.
*
**
***
Class II particle size: >1 to <5
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
® NSF is a registered trademark of NSF International.