INSERT INSTALLATIONS 
 
Insert installations must be vented with 3” or 
4” pipe. Pipe may be single wall stainless 
steel flexible pipe. Vent may terminate within 
chimney beyond a blanking plate or extend 
to the chimney top. See “COMBUSTION AIR 
SUPPLY
” for outside air access information. 
 
The fireplace and chimney should be 
cleaned thoroughly before starting the 
installation. We suggest painting the interior 
of particularly old and dirty fireplaces to seal 
any odors. In zero-clearance fireplace 
installations, when the fireplace opening is 
above the floor or raised hearth, the 
adjustable “Breckwell P2000 Z-C Skirt” (part 
# A-ZC-2KSKRT), or “Breckwell P2000 Z-C 
Legs” (part #A-S-ZCLEGS), can be used to 
bridge the gap between the hearth and stove 
bottom. Refer to figure 13. 
 
A. 
ASSEMBLING THE FLASHING SET 
 
Follow the instructions packaged with the 
P2000 Flashing set part C-P2KI-SMFL, C-
P2KI-MED, or C-P2KI-LG. 
(Refer to Figure 14) 
 
 
 
 
 
 
 
 
 
 
 
 
FIGURE 13 
FIGURE 14 
INSTALLATION 