EXTender 6000 Quick Installation Guide
 
29
 
 
RVP_Over_IP Connect Parameters 
The EXTender utilizes an IP connection to provide remote user connectivity. This means that the local 
area network (LAN) port on the back of the unit is plugged directly into the existing network through an 
RJ-45 connector. The IP Destination (the IP address of the Gateway) must be entered within the MI of the 
EXTender. 
 
Procedure 
1.  Access the Connect Menu from the Main Menu using the following path: 
 
Path: 
Remote->Configuration->Connect 
 
2. Set 
the 
Type parameter to RVP_Over_IP. 
3. Press 
È
 and Ækey to access the RVP Over IP menu. 
 
The following menu appears: 
 
Figure 18:   RVP_IP Menu 
Note: The <Default> setting connects all ports to the same Gateway unit. You can set ports 
individually by simply selecting the port
. 
4. Press 
the 
Æ
 key to access the Default Port menu. 
5. Press 
the 
Æ
 key to the IP Destination parameter. 
6.  Enter the IP address of the Gateway. 
 
Figure 19:   RVP_IP Default Port Menu 
Note: The network administrator must assign this address
7. Press 
the 
Å
 key to accept changes and go back to the Configuration Menu. 
8. Press 
the 
È
 key to the Save option. 
9. Press 
Enter.