Citel 6000 Guía Del Usuario

Descargar
Página de 281
 
PBXgateway
™ 
& EXTender
TM
 
6000 System Administrator’s Guide
 
2 6 4
 
 
Norstar KSU ConneX Configuration  
This section illustrates two variations of Norstar KSU settings to enable ConneX functionality on the 
PBXgateway for the two basic ConneX configurations;  
 
1.  Line Assignment Method - ConneX configuration with no digital set and one remote client,  
2.  ConneX Session Port - Bridged or Ghost configuration where the ConneX client acts as a ghost 
set receiving calls targeted to an actual desk set (either extended from a Remote Extender or 
directly connected to the KSU). 
 
Notes: 
•  The configurations assume that proper call routing has been configured in the KSU, and the 
PBXgateway has been properly programmed for ConneX. 
•  Consult the appropriate Norstar documentation for setting locations and variations to the settings 
listed below (may change depending on KSU). 
•  Caller ID settings are not included. See the appropriate Norstar documentation for the proper 
Caller ID settings available on the system the PBXgateway unit is to be connected to. 
Voice Mail 
If Voice Mail is to be used then the appropriate Norstar Voice Mail setup is required on the desired port. If 
configuring without a desk set then the mailbox will be programmed for the ConneX_Session port, if a 
bridged configuration, then all Voice Mail settings as well as the mailbox will be programmed on the digital 
desk set. See the appropriate Norstar Voice Mail documentation for configuration. 
 
It should be noted that a delay of 1 to 2 rings occurs when the KSU indicates ringing and the remote set 
starts ringing. This requires the Ring Count setting in the Gateway to be at least one greater then the 
number of rings set in the KSU before the call is forwarded to Voice Mail. Third party Voice Mail (Cellular 
company, etc.) forward settings should be at least one ring greater then the Norstar settings to prevent 
ConneX messages from being forwarded to the third party system 
KSU Configuration – Line Assignment Method 
Link Port 
The Link Port is restricted to one Intercom Key assignment and no line appearances to ensure correct 
operation. If the user is required to login via the link from an external set either Direct Ring Transfer of a 
Target Line to the port should be used. The link can also be reached externally via a call to the Company 
Directory if an Automated Attendant is configured. The user can login internally via the port DN at any 
time. 
 
Terminals and Sets 
1. Enable 
Line Pool Access for outbound dialing (PRI or Pool). 
2. Set 
Prime Line to I/C, with a minimum or 1 I/Cs assigned. 
3. Set 
Answer DN to None
4. Set 
Foreward on No Answer and Forward on Busy to None
5. Set 
Do Not Disturb on Busy to N
6. Set 
Handsfree to None
7. Set 
Allow Redirect to Y and Redirect Ring to Y