Citel 6000 Guía Del Usuario

Descargar
Página de 281
 
PBXgateway
™ 
& EXTender
TM
 
6000 System Administrator’s Guide
 
2 6 7
 
 
Definity PBX ConneX Configuration 
The instructions below are applicable for the configuration of Avaya’s DEFINITY ECS running release 3 
or higher: 
SCENARIO #1: Office Phone Used in Conjunction with the ConneX Phone 
There is only one change required on the user’s office extension when he/she wishes to use the ConneX 
phone as a complementary business tool. The number of rings should be increased to six (06) before 
going into voicemail. This is required to allow enough time for the gateway to call the ConneX phone.  
 
Note: No wiring changes are required on this extension.  
Note: This extension MUST be capable of DID
 
1. Perform 
change station to modify the Coverage Path of the user’s office extension to allow it to 
ring 6 times before going into voicemail. Tech Tip: Create a new Coverage Path in the DEFINITY to 
accommodate this “class” of users. 
2. Hit the Enter key on the number pad (far right of keyboard) to save the change made to this 
extension. 
Provisioning a New Extension for the ConneX Phone 
1.  Provision a new extension for the ConneX phone (Ch1) on the DEFINITY. Wire this extension into the 
ConneX PBXgateway on an available port. Note: This extension does NOT require DID capability
2.  Go to Page 1 of the Definity terminal session to configure the CH1 extension. 
3. Change 
Type to a DEFINITY phone set that supports the “analog adjunct” feature. We recommend 
phone set 8411D, however other phones like the 6416D+ and 6424D+ also support the analog 
adjunct feature. Notice the Data Option field appears in the middle of the screen when this change is 
made. Tech Tip: It is NOT necessary for the phone type to match the type used at the office 
extension, since only the first ten (10) line/feature buttons are accessible from a mobile phone.  
4. Complete 
the 
Name field. Be sure to give this extension a clear name (i.e. ConneX Port 1). 
5. Change 
Data Option to analog (notice the page number increases by 1 when this change is made). 
6. Change 
the 
Message Lamp Ext to the user’s office extension. 
7.  Go to Page 2 and set Bridged Call Alerting to Y. 
8. Go to Page 3 of the DEFINITY terminal session for this extension (Ch1).  
9.  On Page 3: Change all call-appr assigned buttons to brdg-appr 
 Btn: assignment # 
 Ext: Office 
Extension. 
Note: Program keys 0-9 on this extension to match the office phone’s keys 0-9. This is required to 
make the features accessible from the mobile phone.  
 
10 Go to last page (note: last page number may vary depending on phone model). Heading should read 
Analog Adjunct
11.  On last page: Assign the Data Extension a new or unused extension (Ch2) on the DEFINITY. This 
extension MUST be capable of DID. This is the extension number that the ConneX users will call to 
access the RCX (DID of the Ch2). Ensure you use a different DID for each user as only one person 
per DID can login. This will either be a DID extension, or accessible through a transfer from a main 
number (i.e. Intuity, Vector, IVR,etc.). 
12.  Type in the extension Name. Give this extension a descriptive name so it is clear what it is being 
used for (i.e. Username B2 - Mobile #1).  
13. Hit the Enter key on the number pad (far right of keyboard) to save all changes made to extension 
Ch1 and its now corresponding extension Ch2.