SAF-TE Implementation
Enclosure Considerations
The DuraStor Storage Subsystem includes SEPs. The controller 
provides information to the user via the enclosure LEDs and the 
host interface.
The controller uses a standard set of SCSI commands to 
communicate with the SEPs via back-end disk channels. This 
communications path is managed by the controller and is 
transparent to the user. However, when the user sets up the 
storage system, SCSI ID conflicts must be avoided and the 
controller’s SCSI ID must be set within the range that the SEP can 
respond to. (Some SEPs are narrow devices and can only see 
certain ranges of SCSI IDs, such as 0-7 or 8-15.)
To set the controller’s SCSI ID on each disk channel:
1
From the System Menu, select Configuration Menu.
2
Select Channel Configuration, and select the channel you wish 
to set up. 
The system prompts you through several items, including the 
Initiator SCSI ID. 
3
Select the appropriate SCSI ID.
Note: 
You may want to do all the channels at one time 
before rebooting the controller.
4
Reboot the controller.
If you are using an enclosure that does not contain an SEP, the 
DuraStor 6200S RAID controller’s internal SAF-TE firmware is not 
activated. In this situation, the internal RAID code operates as 
usual, but the controller cannot signal individual disk slot status 
and array health status to the user via the enclosure LEDs.