6-9
Managing Disk Drives and Enclosures
5
Select the option or number you want to use. See 
 fo
options.
The system confirms that you want to make the change. 
6
Select Yes and press Enter to make the change.
Changing the Additional SEP Settings
You can change four additional SEP settings:
Polling Interval
—Controls the interval (in seconds) at which 
that the controller polls the SEPs for status changes. The default 
setting is five seconds.
Temperature Sensor Status
—Controls whether the controller’s 
onboard temperature sensor provides temperature information 
to the host along with the RAID appliance’s temperature as 
detected by the SEP. The default setting is OFF, which means 
that neither the controller nor the appliance is providing 
temperature information to the host.
Slot Flags (Slot update status)
—Controls whether the controller 
sends commands to the SEP to update the status of each storage 
enclosure slot. The default setting is ON, which means that the 
controller requests status updates from the storage enclosure.
Global Flags (Enclosure update status)
—Controls whether the 
controller sends commands to the SEP to update the overall 
status of the storage enclosure. The default setting is OFF, which 
means that the controller does not request status updates from 
the storage enclosure.
Table 6-1 SEP LUN Options
To:
Do This:
Not assign the SEP an LUN
Type NONE and press Enter
Keep the same LUN for the 
SEP at all times
Type the LUN you want to use 
and press Enter.
This can be any number from 0 
to 63 that is not already in use.