Troubleshooting
Problem: The system hangs during a disk drive scan.
Follow these steps to resolve the problem:
1
Check the storage enclosure to make sure everything is properly 
connected. 
2
Remove and replace the disk drive that failed the scan. 
3
If the storage enclosure and the disk drive work properly, 
replace the controller.
Problem: An active-active controller pair hangs during bootup disk 
drive scan (typically after displaying 
CT_Init
 on the RS-232 display).
Verify that all SCSI channels are connected, cabled, and terminated 
properly. Verify that the controllers are set to their default 
configuration (active-active dual-port mode). 
Problem: An active-active controller pair hangs the host system 
during normal operation or after failing over. 
Verify that all SCSI channels are connected, cabled, and terminated 
properly. 
Problem: An active-active controller pair always fails over after 
booting up. 
Verify that the controller that is failed/killed is set to its default 
configuration (active-active dual-port mode). Verify the same 
SDRAM DIMM sizes are in both controllers. Active-active 
controllers require the same SDRAM DIMM size.
Problem: One controller of an active-active controller pair displays 
the following message when booting: “Other Controller is attempting 
to reset this controller”.
This message appears on failback if the failed controller has not 
been replaced. The message continues to display whenever you 
boot the working controller and change its configuration. To 
eliminate the message, replace the failed controller.