3com S7906E Guía De Referencia
1-21
z
Load sharing is applicable to unicast traffic only.
z
The S7902E switches are designed to work in the load sharing mode, and do not support the
command.
Examples
# Enable the load sharing function of the system.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] loadsharing enable
monitor handshake-timeout disable-port
Syntax
monitor handshake-timeout disable-port
undo monitor handshake-timeout disable-port
View
System view
Default Level
2: System level
Parameters
None
Description
Use the monitor handshake-timeout disable-port command to enable the port down function globally.
With this function enabled, if the SRPU is plugged out or reboots abnormally, all service ports will be
down immediately.
Use the undo monitor handshake-timeout disable-port command to disable the function.
By default, the port down function is disabled.
Examples
# Enable the port down function globally
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] monitor handshake-timeout disable-port
Open port-down function in slot 1 !
Open port-down function in slot 2 !
Open port-down function in slot 3 !