35
J1
SOLENOID VALVE (DISPENSE) - FMD-1 & FMD-2
FIG. 36 DISPENSE SOLENOID VALVE
Location:
 
The dispense solenoid is located on the upper 
left center of the tank.
Test Procedures:
1.   Disconnect the dispenser from the power source.
2.  For FMD-1 disconnect the red and white wires from 
the solenoid valve. For FMD-2 disconnect orange 
and white wires on the right solenoid or the tan and 
white wires on the left solenoid. With the “RINSE/
RUN” switch in the “RINSE” upper  position press 
the  dispense  switch on front of the door.
3.  Check the voltage across the red and white, orange 
and white or tan and white wires with a voltmeter. 
Connect the dispenser to the power source. The 
indication must b:
 
a) 120 volts ac for two wire 120 volt models,
 
b) 120 volts ac for three wire 120/208 volt or 120/240 
volt models,
 
c) 230 volts ac for two wire 230 volt models, after a 
delay of approximately 5 seconds.
4.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #5
If voltage is not present as described, refer to wiring 
diagram and check dispenser wiring harness.
5.  Check for continuity across the solenoid valve coil 
terminals.
If continuity is present as described, reconnect the  wires 
to the solenoid (see Fig. 37), proceed to #6
If  continuity  is  not  present  as  described,  replace  the 
solenoid valve.
6.  Check  the  solenoid  valve  for  coil  action.  Connect 
the  dispenser  to  the  power  source.  With  “RINSE/
RUN” switch in the “RINSE” upper position press the 
dispense switch and listen carefully in the vicinity of 
the solenoid valve for a “clicking” sound  as the coil 
magnet attracts.
7.  Disconnect the dispenser from the power source.
If the sound is heard as described and water will not pass 
through the solenoid valve, there may be a blockage in 
the water outlet before the solenoid valve or, the solenoid 
valve may require inspection for wear, and removal of 
waterborne particles.
If the sound is not heard as described, replace the so-
lenoid valve.
Removal and Replacement:
1.  Open dispenser door and remove the hopper(s)
2.  Remove the two #8-32 screws securing the hopper 
panel to the auger motor mounting panel and two 
#8-32 screws to the whipper mounting panel. Remove 
panel and set aside.
P1666
SERVICE (cont.)
FMD-1
FMD-2
P1665
29112 091307