SERVICE (cont.)
Solenoid Valve
Location:
The  solenoid  valve  is  located  inside  the  rear  of  the 
dispenser on the right side near the bottom.
6.  Check the solenoid valve for coil action. Connect 
the dispenser to the power source. Listen carefully 
in the vicinity of the solenoid valve for a “clicking” 
sound after approximately 5 seconds, as the coil 
magnet attracts the plunger.
7.  Disconnect the dispenser from the power source.
If the sound was heard as described and water will 
not pass through the solenoid valve, there may be a 
blockage in the water line before or after the solenoid 
valve or the solenoid valve may require inspection for 
wear and removal of waterborne particles.
If the sound was not heard as described, replace the 
solenoid valve.
Removal and Replacement:
1.  Remove all wires from the solenoid valve coil.
2.  Turn-off the water supply to the dispenser.
3.  Disconnect the water lines to and from the solenoid 
valve.
4.  Remove the two 8-32 slotted-head screws holding 
the  solenoid  valve  and  mounting  bracket  to  the 
component bracket.
5.  Lift-out the solenoid valve.
6.  Remove the two 10-32 slotted-head screws holding 
the solenoid valve to its mounting bracket.
7.  Securely install the new solenoid valve to its mount-
ing bracket. The direction of flow arrow must be 
pointing towards the tank lid.
8.  Attach the solenoid valve and mounting bracket to 
the component bracket.
9.  Securely  fasten  the  water  lines  to  and  from  the 
solenoid valve.
10. Reconnect the wires, FIG. 6.
Test Procedure:
1.  Disconnect the dispenser from the power source 
and turn-off the water supply to the dispenser.
2.  Check the voltage across the solenoid valve coil 
terminals with a voltmeter. Connect the dispenser 
to the power source. The indication must be:
 
a.) 100 to 120 volts ac for 100 to 120 volt mod-
els,
 
b.) 200 to 240 volts ac for 200 to 240 volt mod-
els,
 
c.) 230 volts ac for 230 volt models,
 
after a delay of approximately 5 seconds.
3.  Disconnect  the  dispenser  from  the  power 
source.
If voltage was present as described, proceed to #4.
If voltage was not present as described, refer to the 
Wiring Diagrams and check the dispenser wiring har-
ness.
4.  Remove both wires from the solenoid valve coil 
terminals.
5.  Check for continuity across the solenoid valve coil 
terminals.
If  continuity  is  present  as  described,  reconnect  the 
wires and proceed to #6.
If continuity is not present as described, replace the 
solenoid valve coil.
FIG. 5 SOLENOID VALVE
FIG. 6  SOLENOID VALVE WIRING
BLU to Liquid Level #2
WHI or RED to Terminal Block
P1778
P1779
10267 011599