SERVICE
This section provides procedures for testing and 
replacing  various  major  components  used  in  this 
dispenser  should  service  become  necessary.  Refer 
to Troubleshooting for assistance in determining the 
cause of any problem.
Component Access
WARNING – Disconnect the dispenser from the power 
source before the removal of any panel or the replace-
ment of any component.
The limit thermostat, liquid level probe, tank heater, 
and temperature sensor are located at the top of the 
dispenser. Access is gained by removing the top lid, 
attached with three 4-40 slotted-head screws.
WARNING – Inspection, testing, and repair of electrical 
equipment should be performed only by qualified service 
personnel. Disconnect the dispenser from the power 
source when servicing, except when electrical tests are 
required and the test procedure specifically states to 
connect the dispenser to the power source.
Contactor .............................................................17
Limit Thermostat ..................................................10
Liquid Level Board ...............................................15
Safety Overflow Switch ........................................11
Solenoid Valve .....................................................12
Tank Heater ..........................................................13
Control Thermostat ..............................................14
The check valve, safety overflow switch, solenoid 
valve, overflow tube temperature sensor, control ther-
mostat and terminal block are located at the rear of the 
dispenser. Access is gained by removing the upper and 
lower rear panels. The upper is attached with six 8-32 
slotted-head screws. The lower is attached with four 
8-32 slotted-head screws. The middle panel must not 
be removed from the dispenser.