KitchenAid 30" Commercial-Style Hood Guía De Instalación

Descargar
Página de 28
9
Range Hood Mounting Screws Installation
The hood attaches to the wall with two mounting brackets with 
adjustment screws and four mounting screws.
1. Determine and mark the centerline on the wall where the 
canopy range hood will be installed.
2. Select a mounting height between a minimum of 
30" (76.2 cm) and a suggested maximum of 36" (91.4 cm), 
above the cooking surface and the bottom of the range hood. 
To this distance, add 16" (40.6 cm) and mark a horizontal line.
3. Mark 2 points on each side of the horizontal line the distance 
shown in “A” below (based on the size of your range hood).
4. Adjust the two adjusting screws on the mounting brackets to 
the lowest point and attach to the wall with the screws 
provided. The screws provided for mounting this hood must 
be fastened into solid wood. Do not fasten into sheet rock 
only. 
IMPORTANT: All screws must be installed into wood. If there 
is no wood to install into, additional wall framing supports 
may be required.
Optional Duct Cover Installation
1. Attach the full-width duct cover to the top of the range hood 
with the screws provided. The duct cover must be attached 
to the top of the range hood before mounting the range hood 
to the wall. For information on ordering the optional duct 
cover, see “Accessories” section.
  
2. Install each bracket on the wall as shown. Make sure the 
screws and brackets are securely fastened to the wall. 
IMPORTANT: Install only the brackets. Do not install the 
hood.
Optional Chimney Extension Installation
1. If a chimney extension is used, attach the extension brackets 
as shown. Make sure that the screws are securely fastened to 
the wall.
 
For information on ordering the optional chimney 
extensions, see “Accessories” section.
Optional Heat Lamp Installation
1. Remove the bottom panel at the rear of the hood by removing 
the screws located at each end.
2. Install the heat lamp kit with the tabs inserted into the 
corresponding slots on the hood and the screws toward the 
front of the hood. Replace the screws to secure it in place.
Complete Preparation
1. Determine and make all necessary cuts in the wall for the vent 
system. Install the vent system before installing the range 
hood. See the “Venting Requirements” section.
2. Determine the location where the power supply cable will be 
run through the wall.
3. Drill a 1
¹⁄₄" (3.2 cm) hole at this location.
4. Pull enough power supply cable through the wall to allow for 
easy connection to the terminal box.
5. If roof or wall cap does not have a damper, attach damper to 
exhaust opening(s) on top of the hood using two Phillips-
head screws.
6. If 48" (121.9 cm) hood is to be connected to 10" (25.4 cm) 
round vent system, install the vent transition piece now. 
A. Distance from center of mounting 
bracket to centerline.
30" (76.2 cm) hood: 
13
³⁄₈" (34.0 cm)
     36" (91.4 cm) hood: 
16
³⁄₈" (41.6 cm) 
     42" (106.7 cm) hood: 
19
⁷⁄₁₆" (49.4 cm)
     48" (121.9 cm) hood: 
22
³⁄₈" (56.8 cm)
B. Mounting screws (4)
C. Mounting brackets and 
adjustment screws
D. Bottom of hood
A. Distance from center of mounting 
bracket to centerline.
30" (76.2 cm) hood: 
13
¹⁵⁄₃₂" (34.2 cm)
     36" (91.4 cm) hood: 
16
¹⁵⁄₃₂" (41.8 cm) 
     42" (106.7 cm) hood: 
19
¹⁵⁄₃₂" (49.4 cm)
     48" (121.9 cm) hood: 
22
¹⁵⁄₃₂" (57.1 cm)
B. Mounting brackets
C. Top of hood
C
L
16"
(40.6 cm)
A
C
D
C
L
B
A
C
L
C
L
11"
(27.9 cm)
A
B
C
A
A. Ceiling
B. Brackets
C. Top of hood
10 
5
/
8
"
(27 cm)
10
¹⁵⁄₁₆
"
(27.8 cm)
23" (58.4 cm) 
max.
12" (30.5 cm) 
min.
A
B
C
10
¹⁵⁄₁₆
"