WARNING
!
TROUBLESHOOTING GUIDE
To avoid injury from accidental starting, always turn switch OFF and unplug 
the tool before moving, replacing the blade or making adjustments. 
TROUBLESHOOTING GUIDE - MOTOR
PROBLEM
PROBLEM CAUSE
SUGGESTED CORRECTIVE 
ACTION
Brake does 
not stop 
blade within 
10 seconds.
1.  Motor brushes not sealed or 
lightly sticking.
2.  Motor brake overheated 
from use of defective or 
wrong size blade or rapid 
ON/OFF cycling.
3.  Arbor bolt loose.
4.  Brushes cracked, damaged, 
etc.
5.  Other.
1.  Inspect/clean/replace brushes. 
See MAINTENANCE section.
2.  Use a recommended blade. Let 
cool down. See REMOVING 
OR INSTALLING THE BLADE 
section. 
3.  Retighten. See REMOVING 
OR INSTALLING THE BLADE 
section. 
4.  Replace brushes.
5.  Contact Sears Service Center.
Motor does 
not start.
1.  Limit switch failure.
2.  Brush worn.
3.  Fuse blown or circuit 
breaker tripped on home 
panel.  
1.  Replace limit switch.
2.  Replace brushes. See 
MAINTENANCE section.
3.  Verify there is electrical power 
at the outlet.
Brush spark 
when switch 
released.
1.   Brush worn.
2.   Other.
1.  Replace brushes. See 
MAINTENANCE section.
2.  Contact Sears Service Center.