Timberk 18 H S8ML Corona Special Manual De Usuario

Descargar
Página de 36
www.timberk.com • Electric air conditioner
9
8. MAINTENANCE
•  Before cleaning unplug the conditioner.
•  Cleaning of the indoor unit and remote control board:
•  Indoor unit and remote control board should be cleaned with a dry soft 
cloth.
•  If the indoor unit is too unclean, moisten the cloth with cold water.
•  It  is prohibited to clean the remote control board with moist cloth.
•  In order to avoid the damage of paint or details of the conditioner, do not 
clean it with brushes and do not leave them on the surface of indoor unit.
•  In order to avoid the damage of surface or deformation of the conditioner 
details, do not clean it with petrol, solvents, cleaning powders or other 
chemically active substances.
•  Before a sustained interruption in the conditioner work:
•  Turn the conditioner on for several hours in the FAN mode. It will allow 
you to dry its inner cavities
•  Unplug the conditioner. Remove the batteries from the remote control 
board. 
•  Checks before starting:
•   Make sure that an air filter is installed.
•  Make sure that air inlet and outlet grilles of the outdoor unit are not 
blocked by foreign objects.
•  Cleaning of air filter
•  Air filter cleans the air entering the conditioner from dust and foreign 
particles. If the filter is contaminated, the conditioner capacity decreases 
sharply.
•  If the conditioner is operated permanently, the filter should be cleaned 
once per two weeks.
•  If the conditioner is installed in a room with dusty atmosphere, then the 
air filter should be cleaned more often.
•  To remove the filter, open the indoor unit panel.
•  Remove air filters. Clean the filter with a vacuum cleaner or rinse it in 
clean water. If the filter is contaminated heavily, clean it with a soft brush 
and wash in diluted washing solution, then dry it in a cool place.
•  While cleaning the filter with the vacuum cleaner, hold it with contaminated 
surface up. While washing the filter in water, hold it with contaminated 
surface down.
•  Do not dry the filter in the sun or near a fire.
•  Set the air filter to initial position and close the panel.
«SLeeP» mode
Button «SLEEP» (Night Care). Using this button, you may turn the sleep 
mode on and off. In this mode, if working for cooling, the conditioner will 
increase temperature by 1 °С an hour  from the specified one within two 
hours. If working for heating, the conditioner will decrease temperature by 
1 °С an hour  from the specified one within two hours. After 10 hours of 
operation the conditioner will turn off automatically.
regulation of treated air flow direction
Regulating the position of deflectors (blinds), set the direction of treated 
air flow ensuring uniform distribution of temperature and the most comfort 
conditions in the room. To change the position of deflectors, use the 
«SWING» button.