Chapter 5    Web GUI Setup and Monitoring  
 
 
 
250 
 
Choose  Manual Data1 or Manual Data2 to only use DATA1 (port 1) or DATA2 
(port 2) for output data. The remaining  redundancy  controls  below  are not 
applicable. 
Choose  Backup: Primary Data1 (default) or  Backup: Primary Data2 to use port 1 
or port 2 as the primary data port and if a physical connectivity  loss occurs, it 
will failover  to port 2 or port 1 (the backup port). 
Choose  Mirroring to send the same data to both port 1 and port 2. The remaining 
redundancy  controls  below  are not applicable. 
3  If Backup: Primary Data1/Data2 is selected as the Mode, choose the redundancy 
Direction. Select  Revertive  to attempt to revert  back to the primary  port when 
using the backup port and the primary port is active again. Choose  Non-
Revertive
 to always use the backup port, regardless  of the condition  of the 
primary port. 
4  In the  Delay Forward field, set the time to switch the data port after the system 
detects a failure, in a range  from 0 to 10000 milliseconds. 
5  In the  Delay Back field, set the time to wait when  reverting  back to the primary 
port once  the primary  link is active again, in a range  from 1 to 120 seconds. 
Note: If Non-Revertive  is selected as the  Direction, this field does not apply. 
6  Click Apply
 
Viewing the Redundancy Status 
The Redundancy Status table displays the latest redundancy  status change. 
The Ports In Use column displays the current output port in use (Data1 or Data2), 
the Change Reason column displays a description  of the reason  for the last 
redundancy  status change  (Link or Setup+Link), and the Change Date & Time 
column displays the last date and time the redundancy  status changed.   
 
Viewing the Link Status 
The Link Status table displays the port information,  such as the status speed, 
duplex, and crossover.  Port 1 is the management  port and port 2 is the data port.