Reliability
You expect a technically convincing solution, with the flexibility to adapt to ever  
increasing requirements. Easy to operate and designed for easy maintenance. 
Compact Design
UPS electronics and battery are combined in only 2U of rack 
space. With the flip-over front cover it is easy to change the 
hot-swappable battery or to add external battery packs. 
Autonomy time can be extended 
by preconfigured battery packs. The 
number of connected battery packs 
will be detected automatically. All 
battery packs are hot-swappable and 
can be connected without discon-
necting the UPS, simply open the 
cover to swap.    
Communication options
Extraordinary communication options are provided by the 
several interfaces including programmable potential-free  
contacts, emergency power off 
switch, RS232, USB and an extension 
slot that can be used in parallel mode 
with RS232/USB. The extension slot is 
compatible with optional accessories 
such as relay cards or SNMP adapter.
Battery management
The improved battery charging technology provides quicker 
charging time with a gentle charging 
characteristic. The battery manage-
ment system is able to differentiate 
between initialization during setup, the 
battery charging phase (temperature 
compensated) and the standby phase. 
This enables the system to extend 
battery lifetime as there is a decrease 
of pole corrosion. An uncoupled 
battery charger avoids battery heating and inverter reflection 
effects.
Innovative output control
All UPS outlets are equipped with an innovative lock mechanism 
that prevents the connected cables from accidental disconnection. 
The UPS outlets can be managed by 
the user, allowing applications to be 
prioritized in the event of a power 
failure. These programmable outlets 
allow for easy load management or  
load shedding, enabling the user full 
flexibility in power distribution and 
energy management.
Graphical display
The multi-language graphical display supports better read-
ability. It displays several parameters of the input, UPS mode 
and the output. Three LEDs at the top of the display indicate 
the current operating mode. From 
the control panel the user is able 
to configure the UPS setting and 
activate an audible alarm. All 
events are logged by an internal 
logger to allow events analysis. 
From the settings menu the user 
can control the UPS outputs 
according to the battery capacity 
and the delay after a power failure 
for the UPS to initialize a shut down. It is also possible to 
schedule for a battery test either daily, weekly or monthly. 
Additional features
With the converter mode the UPS can be used as frequency 
converter or works as a line conditioner with an effective 
output voltage of 200V or 208V.