Sony HDW-F500 Manual De Usuario
4-3 TC Menu
4-26
Chapter 4
Menu Settings
Chapter 4 Menu Settings
4-3-6 Inserting VITC input source
(VITC)
(VITC)
Press the
[F10] (VITC) button to select the VITC
source to be written in the video signal AUX data area.
TCG: Inserts values generated by the internal time
code generator into the VITC.
V IN: Inserts the VITC from the video input signal
directly.
4-3-7 Selecting CTL Display
Mode (TAPE TIMER)
Mode (TAPE TIMER)
Press the ALT button, then the
[F1] (TAPE TIMER)
button to select a 12-hour or 24-hour clock for the
CTL display.
CTL display.
+/–12H: 12-hour clock
24H: 24-hour clock
24H: 24-hour clock
4-3-8 Presetting Pull Down Time
Code (PDPSET MENU)
(when HKDV-507 is installed)
Code (PDPSET MENU)
(when HKDV-507 is installed)
To preset the pull down time code, follow the steps
below.
below.
1
Press the TC button, then press the ALT button.
The ALT+TC menu appears.
2
Press the
[F2] (PDPSET MENU) key.
The PDPSET menu appears.
3
Press the
[F1] (PRESET MODE) key to select 24F
or 30F time code to be preset. The selected time
code is framed with the thick line.
24F: Presets the 24 frames time code. The A
code is framed with the thick line.
24F: Presets the 24 frames time code. The A
frame of the pull down sequence is preset.
30F: Presets the 30 frames time code. The A
frame of the pull down sequence is preset.
4
•When 30F is selected in the step 3,
Press the
Press the
[F6] (PDTC DF/NDF) key to select DF
or NDF.
This selection is effective only for 30F time code.
DF: Drop frame mode
NDF: Non-drop frame mode
auto: The unit switches the running mode (DF/
This selection is effective only for 30F time code.
DF: Drop frame mode
NDF: Non-drop frame mode
auto: The unit switches the running mode (DF/
NDF) automatically according to the frame
frequency of the unit. When the frame
frequency is 23.976 Hz, the unit switches to the
drop frame mode and switches to the non-drop
frame mode when it is 24 Hz.
frequency of the unit. When the frame
frequency is 23.976 Hz, the unit switches to the
drop frame mode and switches to the non-drop
frame mode when it is 24 Hz.
•When 24F is selected in the step 3,
Skip this step.
Skip this step.
5
Enter the time code data in the data entry window
with numeric keys.
with numeric keys.
1
3
2,7
6
5
4
C H . C O N D
G R E E N
P D P S E T
2 4 F T C
00
Ó
00
µ
00
ß
00
ƒ
3 0 F T C
00
Ó
00
µ
00
ß
00
ƒ
P D T I M E
S E T
R E M A I N - T
L 1 1 3 m i n
P D T C
D F / N D F
E X I T
N D F
2 4 F
P R E S E T
M O D E
T C R 0 0 : 0 0 : 0 0 : 0 0
C H . C O N D
G R E E N
P D P S E T
2 4 F T C
00
Ó
00
µ
00
ß
00
ƒ
3 0 F T C
00
Ó
00
µ
00
ß
00
ƒ
P D T I M E
S E T
R E M A I N - T
L 1 1 3 m i n
P D T C
D F / N D F
E X I T
D F
2 4 F
P R E S E T
M O D E
T C R 0 0 : 0 0 : 0 0 : 0 0
0 1 0 0 3 0 0 0
Data entry
window
window