Installation
27
510969
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Electrical Connection
Three-Wire Power Cord
1. Remove the screw and terminal block access 
cover from the rear of the dryer cabinet.
2. Insert ends of direct wire through power supply 
hole (containing proper strain relief) in rear of 
dryer cabinet. Refer to Figure 19. Connect the 
power cord, or direct wiring, to the appropriate 
terminal block terminals using the three wire-
binding
 (10-32 x 3/8") screws from the 
accessories pack in the envelope shipped inside 
the dryer cylinder.
 If the dryer had previously 
been connected with a four-wire power cord, 
remove the four-wire power cord by reversing 
procedures under Four-Wire Power Cord 
instructions.
IMPORTANT: Use only a U.L. listed No. 10 A.W.G. 
(copper wire only) three conductor power supply 
cord kit rated 240 Volts (minimum) 
30 Amperes and labeled as suitable for use in a 
clothes dryer.
3. Tighten these wire-binding screws firmly.
IMPORTANT: Failure to tighten these screws 
firmly may result in wire failure at the terminal 
block. 
4. Secure the strain relief to the power cord, or 
wires, where they enter the dryer cabinet.
5. Check the continuity of the ground connection 
before plugging the cord into an outlet. Use an 
acceptable indicating device connected to the 
center grounding pin of the plug and the green 
screw on the back of the cabinet.
6. Reinstall access cover and screw. 
Figure 18 
The dryer is grounded to neutral conductor 
at the terminal block. If the dryer is installed 
in a mobile home, or if local codes do not 
permit grounding through the neutral, 
proceed as shown on Four-Wire Power 
Cord
 instructions.
W134
To reduce the risk of electric shock, 
disconnect the electrical service to the 
dryer before proceeding.
W135
WARNING
D607I
1
Grounding Pin
3
Indicating Device (Must show continuity)
2
Ground Screw on Back of Cabinet
D607I
2
1
3