Monessen Hearth mhsc eyf18 Manual De Usuario

Descargar
Página de 36
65D1009 
13
Heater in Fireplace or Firebox
Heat 
Resistant
Material
Hood
12"
6" - 10 "
2
1
/
2
"
8"min.  13"     18"        20"
Heater in 
Fireplace or 
Firebox
Heat 
Resistant
Material
10" or less
20" min.  32"
CLEARANCES 
AND
 HEIGHT REQUIREMENTS
TABLE B - Heat Resistant Material Heights and Mantel Location
Figure 8 - Minimum Mantel Clearance 
with No Hood
Figure 7 - Minimum Mantel Clearance 
with Hood 
Example:  The bottom of the mantel may project from the 
wall a maximum of 10" at a minimum of 32" 
above the opening. 
Example:  
A mantel may project from the wall a maxi-
mum of 2 
1
/
2
" at a minimum of  13" above the 
opening and a maximum of 10" at a minimum 
of 18" above the opening. 
HEAT RESISTANT MATERIAL 
MEASUREMENT
 REQUIREMENTS FOR SAFE INSTALLATION WITH WOODEN MANTEL, SHELF 
OR OTHER COMBUSTIBLE PROJECTION
20" or more
Hood not required. Observe profiles (side elevations) shown in Figure 8.
8" to less than 20"
Install hood (CABR/CABL) and observe profiles shown in Figure 7OR extend heat 
resistant material to at least 12" and observe profiles shown in Figure 8.
Less than 8"
Extend heat resistant material to at least 8", install hood (CABR/CABL) and observe 
profiles shown in Figure 7OR extend heat resistant material to at least 12" and observe 
profiles shown in Figure 8.