Cisco Systems 11500 Series Manual De Usuario

Descargar
Página de 206
C-9
Cisco 11500 Series Content Services Switch Hardware Installation Guide
78-13884-03
Appendix C      Troubleshooting
Troubleshooting the Boot Process
SCM Boot and Verification of the Modules
After the CSS 11503 or CSS 11506 completes the OffDM boot process, it displays 
the main banner and starts the Online Diagnostic Monitor (OnDM). During 
OnDM, the SCM downloads software to each of the modules and boots the 
modules. Then, the SCM verifies that each module is functioning.
If there is a failure on a module, the SCM attempts to boot the module three times. 
If the SCM is unsuccessful, the CSS generates the following log message and 
saves it in the boot.log file:
CHMGR: Slot slot/subslot had diagnostic failures - NOT STARTING UP
Then the SCM shuts down the slot and no longer recognizes it. If you use the show 
chassis
 command, the slot does not appear. If a module failure occurs:
1.
Power down the CSS.
2.
Reseat the module.
3.
Power on the CSS.
If reseating the module does not correct its failure, replace the module.
For additional information on troubleshooting the modules during normal CSS 
operation, see 
. For information on log files, see 
.