Power Distribution PWA
Fuses for
Motor Drive
Circuit
 
Figure 36 Motor Drive Circuit Fuses 
Relay PWA Replacement 
If a relay PWA needs to be replaced, follow the procedure in Table 37 to access and replace the PWA.  
 
 
Disconnect power before opening the actuator case. A potentially lethal shock 
hazard exists inside the case if the unit is opened while powered. 
 
 
Table 37 Relay PWA Replacement Procedure 
Step 
Action 
Remove AC power from actuator. 
Remove the six screws and the cover of the actuator case. See Figure 35. 
Lay assembly down on a flat surface.   
Disconnect the wire connector from the relay PWA.   
Carefully remove the relay PWA. Pry the locking tabs of the card guides away to unlock the 
PWA and slide it out from the card guides.    
Install the replacement relay PWA by sliding it into the card guides until it mates with the 
backplane board.  Locking tabs on the card guides will engage to secure the PWA in place.   
Plug in wire connector to relay PWA.  