AV8OR User’s Guide                                                         Appendix 
 
Pub. No D200803000008         Page 7-6     Revision July 2008. 
© Honeywell International Inc. Do not copy without express permission of 
Honeywell. 
 
Figure 7-1: External GPS Setup Screen 
 
The interconnect between the Bendix/King KLN 94 and the 
AV8OR is as follows:
 
 
KLN 94 Signal Name KLN 
94 
Pin Out 
AV8OR 
Signal Name 
AV8OR Pin 
Out 
GENERAL RS-232 OUT  P941-2 
RS 232 RX 
DB9-2 
GENERAL RS-232 IN 
P941-1 
RS 232 TX 
DB9-3 
AIRCRAFT GROUND 
P941-14 
GROUND 
DB9-5 
 
The wiring interconnect between the GNS 430/430W/530/530W and 
the AV8OR is as follows:
 
GNS430/530 Signal 
Name
 
GNS430/530 
Pin Out
 
AV8OR 
Signal 
Name
AV8OR Pin 
Out
 
GPS RS-232 OUT 1
 
P5001-56
RS 232 RX
DB9-2
GPS RS-232 IN 1
 
P5001-57
RS 232 TX
DB9-3-
AIRCRAFT GROUND
 
P5001-77,78
GROUND
DB9-5