Faceplate Removal - H5 ELEMENT: After removing 
top cover, remove the two upper screws securing the 
faceplate. Carefully lift faceplate straight up until the 
three lower screws clear the key holes.
The check valve, electronic control assembly, safety 
overfl ow switch, solenoid valve, overfl ow tube tempera-
ture sensor and terminal block are located at the rear of 
the dispenser. Access is gained by removing the upper 
and lower rear panels. The upper is attached with six 
8-32 slotted-head screws. The lower is attached with 
four 8-32 slotted-head screws. The middle panel must 
not be removed from the dispenser.
P1770.30
42311 022311
:$51,1*
9HU\+RW:
DWHU
8VH:
LWK&DUH
  
The check valve, electronic control assembly, over-
fl ow protection switch, solenoid valve, overfl ow tube 
temperature sensor, triac assembly (EARLY MODELS 
ONLY) and terminal block  are located on the side of 
the dispenser. Access is gained by removing the side 
panel. The panel is attached with eight 8-32 slotted-
head screws. 
P878.30
SERVICE
WARNING – Disconnect the dispenser from the power source before the removal of any panel or the replacement 
of any component. WARNING - Inspection, testing, and repair of electrical equipment should be performed only 
by qualifi ed service personnel. Disconnect the dispenser fromthe power source when servicing, except when 
electrical tests are required and the test procedure specifi cally states to connect the dispenser to the power source.
 