The Ring Statistics Screen
HSIM-F6 User’s Guide
3-11
3.6.1
HSIM-F6 FDDI Ring Statistics Screen Fields
The HSIM-F6 FDDI Ring Statistics screen allows the user to monitor the 
current HSIM-F6 operational status.
The following list describes the Ring Statistics screen fields:
RING STATE
Displays the current ring state. The possible ring states are as follows:
Ring-Op -
The ring is functioning correctly.
Isolated -
The HSIM-F6 is not attached to the ring.
Non-Op -
The HSIM-F6 is attempting to enter the ring.
Detect -
The claim (beacon) process of the FDDI ring 
protocol has exceeded one second. There may be a 
problem.
Non-Op-Dup -
The ring failed to complete the claim (beacon) 
process. This usually indicates a duplicate FDDI 
address.
Ring-Op-Dup -
The ring is operational, but a duplicate FDDI 
address may be present somewhere on the network.
Directed -
The claim (beacon) process did not complete 
within ten seconds. The HSIM-F6 is sending 
directed beacons to indicate a problem.
Trace -
A problem has been detected with the HSIM-F6 or 
the nearest active upstream neighbor (NAUN). A 
trace is being sent to notify the nearest active 
upstream neighbor of the problem.
RING-OP COUNT
The Ring-Op Count keeps track of the number of times the FDDI ring has 
initialized since the last time the HSIM-F6 (or host device in which it 
resides) was reset. If this number grows steadily over a brief period of 