Beijing Telestone Technology Co. Ltd WFDS-RUA Manual De Usuario

Descargar
Página de 14
                                                 
WFDS User Manual 
 
 
 
TELESTONE Proprietary 
© 2009 TELESTONE. All rights reserved. 
 
 
 
 
 
 
 
 
 
 
UL: RU receives RF signal from antenna UL transmitted from coaxial cable. Signal is 
enlarged by low noise amplifier then transmitted by optical modules. And at last optical 
signal is sent to expansion unit or main unit. 
The power of the RU is supplied by upper unit. 
2.3.2 RU 
Specifications 
 
  Dual Mode Remote Unit 
Specification Description 
GSM  850MHz: 
UL824-849, DL869-894 
Working 
frequency
MHz) 
PCS  1900MHz: 
UL1850-1910, DL1930-1960 
DL output RF power(dBm) 
21 
Noise Figure(dB) 
≤6 
Max Gain(dB) 
35 
Gain Adjusting(dB) 
≥30, 1dB step 
modulation(dBc) 
-45 
≤-36/100KHz@9KHz-1GHz 
Spurious emission  (dBm) 
≤-30/1MHz@1GHz-12.75GHz 
ripple in the band(dB) 
≤6 
RF Port Input VSWR 
≤2.0 
delaying Time(µs) 
≤1µs 
MTBF (h)
 
100,000 hour 
Fiber Connector 
1 pair FC/APC Connector 
RF Connectors 
1 N-type, female 
Power consumption (W)
 
20 
Dimensions 260mm×250mm×75mm 
Weight (Kg) 
Operating Temperature (°C) 
-10~+50℃ 
Operating Humidity, non-condensing 
5% to 95%