Culligan International Company 01020553 Manual De Usuario

Descargar
Página de 74
 
Custom­izing the Setup 
28
 27
  CULLIGAN GLOBAL ELECTRONIC CONTROLLER
The controller is designed to simplify the setup and installation process by making some default recommendations 
during the Initial Setup.  The default settings are designed to be appropriate for most common installations.  
Default Settings
Downflow Brining
2
Standard Mesh Resin
1
Blue/Beige Eductor
1
0.45 GPM Brine Flow Control
1
0 PPM Iron
1
> 40 psi water pressure
1
 
NaCl Salt
1
Time of Regen = 2:00 AM
2
Regen Time = Delayed
2
Dosage (calculated)
2
Predict Mode ON
3
30% Reserve Capacity
2
Time Clock Backup = OFF
3
Day-of-week Regen = OFF
3
Pre-Rinse Mode = OFF
1
 
1
= these items are changed on the Main Menu / Advanced / System Setup Menu
2
= these items are changed on the Main Menu / Advanced / Regen Setup Menu
3
= these items are changed on the Main Menu / Advanced / Regen Trigger Menu
There may be times when the installer would prefer to override the default regeneration selections.  See 
Advanced Setup Menu, Regeneration Setup Menu or Regeneration Trigger Menu for information on changing 
default selections.
Advanced System Set-up Menu
• 
Press the UP
  
„ 
or DOWN
  
‰ 
arrow to scroll to menu item
• 
Press the CHECKMARK
   
key to select a menu item
•  Press the 
UP
   
„ 
or 
DOWN
  
   
arrow to change a selection
• 
Press the CHECKMARK
   
key to save your selection
Default Values are shown for each selection
Scroll to ADV SETUP and select
Select SYSTEM SETUP
system ok
7:32 am 2-1-08
 > 5) Adv Setup
 > 1) system Setup
Customizing the Setup