Culligan International Company 01020553 Manual De Usuario

Descargar
Página de 74
Installation of Accessories
Refer to page 46 for more information on the operation of the Aux Outputs. Refer to the instructions below for step 
by step setting of these values.
• 
Press the UP
  
„ 
or DOWN
  
‰ 
arrow to scroll to menu item
• 
Press the CHECKMARK
   
key to select a menu item
•  Press the 
UP
   
„ 
or 
DOWN
  
   
arrow to change a selection
• 
Press the CHECKMARK
   
key to save your selection
Default Values are shown for each selection
Scroll to ACCESSORIES and select
Select AUX OUTPUTS
Select AUX OUT 2
Can be set to NORMALLY OFF or NORMALLY ON. For brine reclaim, set to 
NORMALLY OFF.
This can be set to any cycle. For brine reclaim, change this to BRINEDRAW POS.
This is the activation delay. For brine reclaim, leave at zero (0).
Set this value to the number of minutes needed for aux 2 to be activated. Refer to the 
brine reclaim manual, 01018946, for recommended settings.
Now set AUX OUT 3
Select AUX OUT 3
Can be set to NORMALLY OFF or NORMALLY ON. For brine reclaim, set to 
NORMALLY OFF.
This can be set to any cycle. For brine reclaim, change this to BRINEDRAW POS.
 > 4) accessories
 > 4) aux outputs
 > 2) aux out 2
  3) aux out 3
aux2 cycle type 
normally off
aux out 2
service pos
aux2 out
delay 0 mins
aux2 out
on 0 mins
  2) aux out 2
 > 3) aux out 3
aux3 cycle type 
normally off
aux out 3
service pos
 
Installation of Accessories 
44
43
  CULLIGAN GLOBAL ELECTRONIC CONTROLLER
system ok
7:32 am 2-1-08