Culligan International Company 01020553 Manual De Usuario

Descargar
Página de 74
Manual cycling can be performed when the unit is starting either in SERVICE or while it is already within any 
portion of the REGENERATION process. If the unit is currently regenerating, the name of the current cycle position 
and the number of minutes remaining in the current cycle position will be displayed.
From the home screen, press the DOWN arrow to ADV. SETUP.  Press the CHECK 
MARK button.
Press the DOWN button to scroll to DIAGNOSTICS. Press the CHECK MARK button at 
DIAGNOSTICS.
Press the DOWN button to scroll to MOTOR CONTROL. Press the CHECK MARK but-
ton at MOTOR CONTROL.
If control is not in regeneration, this is shown. 
To cycle the control valve without stopping press the CHECK button.  To stop the motor at 
the end of each cycle press the UP arrow.
Menu
Status
MOTOR AT POS S
Motor at service position
MOTOR AT POS B
Motor at backwash position
MOTOR AT POS E
Motor at brine draw/slow rinse position
MOTOR AT POS F
Motor at fast rinse/refill position
If cycling the control during regeneration, this screen is shown after MOTOR CONTROL.
Press the CHECK MARK button to change REGENERATION setting.  Press the UP 
or DOWN arrow to move to NEXT CYCLE, END REGEN NOW or END/CAN-
CEL TRIG.   Press the CHECK MARK when the correct REGENERATION setting is 
displayed.
system ok
7:32 am 2-1-08
 > 5) adv setup
motor at pos s
up: forward
 > 5) diagnostics
 > 5) motor control
backwash minutes left: 8
>next cycle
Manual Cycling
 
Manual Cycling 
50
49
  CULLIGAN GLOBAL ELECTRONIC CONTROLLER