Radio Transmission Characteristics 
The Edit Radio Transmission Characteristics option allows the user to modify several different parameters 
in the transceiver. Many of these parameters must be maintained throughout the network for proper 
functionality.  
Note:   This menu is only for the sophisticated user who has a good understanding of the principles of 
radio data transmission.  
The settings for the Slave(s) not determined by the Master are RF Xmit Power, Slave Security, Retry 
Time Out and Hop Table Size, Hop Table Version, and Hop Table Offset. 
 
Note: Above image from LRS455. Configuration will be the same. 
Edit Radio Transmission Characteristics  
S
ETTING 
X
MIT AND 
R
CV 
F
REQUENCIES 
 
The 400MHz Data Transceiver has the option to operate in a Frequency Division Duplex mode by 
transmitting on one frequency and receiving on another.  
The LRS400S transceivers must be programmed to operate on the appropriate frequency. To program 
the transceiver for single channel operation, enter the frequency, in Megahertz, into the TX and RX 
Frequency slots.  
If the transceivers are to operate in Frequency Division Duplex, the TX and RX Frequency slots will have 
different frequencies assigned.