Multiple TX10K Transmitters 
When working with multiple TX10K Transmitters in close proximity, 
the Infrared Receivers may be intentionally covered with an 
opaque object in order to eliminate an inadvertent configuration 
change to an adjacent TX10K.  Also, removing power 
(disconnecting the battery) or putting the TX10K in standby mode 
will prevent the RM10K from changing the configuration of a 
transmitter. 
 
 
Product Safety 
 
The user assumes all risk and liability for the installation and 
operation of this equipment.  Each application presents its own 
hazards.  Typically, certain system components are strapped to a 
rotating shaft.  If sufficient care is not taken to properly secure 
these components or accessories connected to them, they can be 
flung from the shaft, causing damage to the components or to 
property or persons in the vicinity.  Use more than enough tape: 
10 or more wraps is not too much.   
 
 
Installation Procedure 
 
The TorqueTrak 10K System is designed for ease of use.  The 
procedure for a typical setup on a shaft for obtaining torque 
measurements is detailed in the Field Testing section below.   
 
It is recommended that the user bench test the instrument to 
become familiar with the various operational features prior to 
conducting tests in the field. The BS900 Bridge Simulator and 9V 
Battery Connector have been provided for this purpose.  See the 