Operating Instructions 
 
 
Warning and Failure Indications 
 
30 
VHF Transceiver Family 620X 
0638.420-071 Issue 03 July 2015 
2.13. 
Warning and Failure Indications 
Display Contents 
Description 
LOW BATTERY
IC
118.005
 
Appear in 3-second 
cycle 
"LOW BATT" is indicated if the supply voltage of the 
transceiver is below the threshold defined in the 
installation setup. 
The transceiver is still operable but may have a 
reduced performance depending on supply voltage. 
Possible reasons: 
Accumulator capacity problems (gliders), 
Power interrupts, 
General power supply problems, 
Setting for low battery threshold too high 
STUCK PTT
IC
118.005
 
Appear in 3-second 
cycle 
"STUCK PTT" is indicated after 120 seconds of 
continued transmission. The transceiver goes back 
to receive mode even if the PTT line is still active 
(GND). 
For initiating a new transmission, the PTT line needs 
first to become inactive (open). 
Possible reasons: 
Transmission lasts more than 120 seconds. 
PTT-key is stuck. 
PTT line permanently grounded (short circuit in 
installation). 
TX HOT
IC
118.005
 
Appear in 3-second 
cycle 
"TX HOT" is indicated if the internal device 
temperature exceeds +90 °C. 
Transceiver is still operable. Performance of 
transmitter is reduced. 
Possible reasons: 
Very hot environmental temperature, long 
transmissions times and insufficient airflow 
conditions.  
FAILURE
IC
118.005
 
Appear in 3-second 
cycle 
The transceiver has detected an internal failure 
during normal operation. 
Depending on failure reason, the device may still be 
operable with degraded performance, or not 
operable at all. 
Possible reasons: 
Specified environmental conditions 
HW or SW failure inside the transceiver. 
Contact maintenance shop for assistance.