Wavetec FZCO WT-AH Manual De Usuario

Descargar
Página de 36
QC Guide of Active Hub  
 
 
Jul. 13 
32 
3-  Capacitor Verification 
Electrolytic Capacitor: 
All electrolytic capacitor can be verified visually, values are written on the capacitor. 
C29, C30 are 470uf/25V. 
Ceramic Capacitor:  
C1, C2, C3, C4, C5, C6, C7, C8, C9, C10, C11,C12, C13, C14, C15, C16, C17, C18, C19, C20, C21, C22, C23, C27, C31, C32, 
C33 are 0.1uF capacitor randomly de-solder 2 capacitors and measure the value with the help of LRC meter and for 
other just visually verify that they are of same package. 
C26, CE1, CE2, CE3, CE4
 
are 10uf tantalum capacitor randomly de-solder one capacitor and measure the value with 
the help of LRC meter and for other just visually verify that they are of same package. 
In the same manner check all the ceramic capacitors, if it is used in multiple location than only de-solder one 
capacitor and other visual verified. 
4-  Connector verification 
Check all RJ45 block connector used in main controller PCB (PT0012M), inside of all connector “GLG” should be 
written as shown in the figure below. 
 
 
RJ45 Block Connector used in Main controller PCB 
 
 
Make sure on the programming connectors of Main Controller PCB should be 2.54mm pitch as shown below.