Finder 67.22.9.012.4300 PCB Mount Relay 67.22.9.012.4300 Hoja De Datos

Los códigos de productos
67.22.9.012.4300
Descargar
Página de 6
3
Example: 67 series solar relay, single PCB terminals, 2 pole NO, ≥ 3 mm contact gap .
Ordering information
A: 
Contact material
4 = Standard AgSnO
2
B: 
Contact circuit
3 = NO, ≥ 3 mm contact gap
5 = NO, ≥ 5.2 mm contact gap
Series
Type
2= Single PCB terminals, 1.5 mm gap 
between PCB and relay base
No. of poles
2 = 2 pole 
3 = 3 pole
Coil version
9 = DC
Coil voltage
See coil specifications
2
3
4
3
9
D: 
Special versions
0 = Standard
1  = Wash tight (RTIII)
C: 
Options
0 = None
S = Version suggested for 100 A 
switching, provided the 
3 contacts are connected in 
parallel (only 67.23...430xS)
0
0
A
B
C
D
.
.
.
.
0 1 2
6 7
Insulation according to EN 61810-1
Nominal voltage of supply system
V AC
400/690 3-phase
400 1-phase
230/400
Rated insulation voltage
V AC
630
400
400
Pollution degree
3
Insulation between coil and contact set
Type of Insulation
Reinforced
Overvoltage category
III
Rated impulse voltage
kV (1.2/50 μs)
6
Dielectric strength
V AC
4,000
Insulation between adjacent contacts
Type of Insulation
Basic
Overvoltage category
III
Rated impulse voltage
kV (1.2/50) μs
6
Dielectric strength
V AC
2,500
Insulation between open contacts
Type of disconnection
Micro-disconnection *
Full-disconnection
Overvoltage category
III
Rated impulse voltage
kV (1.2/50) μs
4
Dielectric strength
V AC
2,500 (67.xx-4300) / 3,000 (67.xx-4500)
Other data
Bounce time: NO 
ms  2
Vibration resistance (10...150)Hz: NO
g  15
Shock resistance 
g  35
Power lost to the environment 
without contact current
W
1.7 (67.xx-4300) / 2.7 (67.xx-4500)
with rated current
W
8.5 (67.xx-4300) / 9.5 (67.xx-4500)
Recommended distance between relays mounted on PCB
mm
≥ 20
* with overvoltage category II: Full-disconnection
Technical data
II-2014, www
.finder
net.com
A
67 Series - Solar relay 50 A
67
SERIES