Slv 114730 GU10 Acrylic glass (matt), Aluminium 114730 Manual De Usuario
Los códigos de productos
114730
1. Use as directed:
This product serves exclusively lighting purposes and may:
only be used with a voltage of 230V ~50Hz.
only be used in dry condition,
only be used in dry condition,
not in damp or dirt-endangered rooms.
not in areas of high air humidity.
not in areas of high air humidity.
not be exposed to strong mechanical loads or to strong
contamination.
only be installed and operated after a condition inspection if the
product is dirty or has been moistened through storage.
not be modified or converted.
If these points named above are not adhered to, a short circuit or
electrical shock may occur!
2. Technical Data:
Operating voltage:
230V ~50Hz
Safety
class:
I
Bulb:
QPAR51, GU10, max. 50W
Dimensions
(L/W/H):
8/8/11
cm
Weight:
0,32
kg
Importeur:
SLV
Elektronik
GmbH
3. Installation
The electric connection may be executed only by an electric expert
who is familiar with the valid directives!
Caution: Switch off the power of the mains supply line or
respectively of the connection lead before doing any works
.
Use only
parts, which are supplied with the product or are described as accessories!
Otherwise the product or the installation might not be sufficiently safe.
Installation place:
The product is suited for ceiling installation.
Make sure that the product is mounted on a stable, even and tilt-fixed
background.
The light exit should be placed at least so far from the illuminated surface,
as indicated as minimum distance on the type plate of the luminaire:
Otherwise the product or the installation might not be sufficiently safe.
Installation place:
The product is suited for ceiling installation.
Make sure that the product is mounted on a stable, even and tilt-fixed
background.
The light exit should be placed at least so far from the illuminated surface,
as indicated as minimum distance on the type plate of the luminaire:
. Pay special caution to easily inflammable objects (e.g.
curtains).
Separate Installation Steps
Remove the mounting bracket from the fitting by loosening the two
Separate Installation Steps
Remove the mounting bracket from the fitting by loosening the two
screws on the side of the canopy.
Determine the place of installation and mark the holes to be drilled. Note
that the cable outlet of the mains supply corresponds with the cable inlet
of the fixture. Do not damage the power supply line, e.g. by drilling,
screws or strong bending.
of the fixture. Do not damage the power supply line, e.g. by drilling,
screws or strong bending.
Fasten the mounting bracket to the mounting surface.
Electrical Connection
Electrical Connection
The product must be able to be separated by an all pole separation
from the current supply.
Equip the three wire ends with protective tubes.
For electric connection attach the black or brown wire (live conductor)
For electric connection attach the black or brown wire (live conductor)
of the mains supply with the clamp L and the blue wire (neutral
conductor) of the mains supply with the clamp N. The green-yellow
wire (protective conductor) of the mains supply has to be tightly
wire (protective conductor) of the mains supply has to be tightly
screwed into the earth clamp
of the product.
Now fasten the fitting back on the mounting bracket. Do not forget to
apply the toothed washers!
Inserting the bulb: Use the sucker to insert the bulb. Screw the bulb
into the socket with a slight turn.
Ensure that the light fixture holds securely!
The product is now ready for operation.
The product is now ready for operation.
4. Operation
:
Information for the user:
Operate the product only if it is working correctly. Switch off the product
with a malfunction immediately and operate it again only after examination
by an electrical specialist. This is the case, when:
visible damages appear.
the product does not work.
smoke, steam or crackling sounds appear.
an overheating is recognisable.
Repairs of the product or work on mains voltage-prominent sections may
only be carried out by qualified electricians.
Warning: Here exists mortal danger from an electric shock!
How to avoid failure and fire risk:
Do not cover the product - provide free air circulation!
Do not hang or fasten anything on the product, especially no decoration.
Do not cover the product - provide free air circulation!
Do not hang or fasten anything on the product, especially no decoration.
Never let children play unsupervised with electric products! Children
can not always estimate dangers in dealing with electric energy correctly.
What is to do if a bulb is defect or does not work?
Disconnect the product from power, before you exchange the bulbs.
Disconnect the product from power, before you exchange the bulbs.
Caution: Let the bulb cool down first before replacement – otherwise
considerable risk of injury exists because of the hot surface.
Replace the bulbs only with bulbs of the same data like socket, power
and capacity. Every other sort of bulb can lead to damages of the light.
Replacing the bulb: see Installation.
5. What else has to be considered?
Disconnect the product from power, before you…
clean or maintain the product.
do any works on the product or its components (electric expert).
clean or maintain the product.
do any works on the product or its components (electric expert).
Art.-Nr. 114730/40 08/2007
© by SLV Elektronik GmbH
Daimlerstr.21-23, 52531 Übach-Palenberg, Germany
Technical Details are subject to change.
Technical Details are subject to change.
Duplication prohibited !
ENGLISH
Instruction Manual
for ceiling fitting
for ceiling fitting
114730/40
Please read carefully and keep for further reference !
L
N