9
Installation
SPARmatic Zero can be quickly and easily mount-
ed on all common valves (see adapter table). It 
can be installed without grime and water spots 
because the heating circuit is not interrupted.
1.  Turn the manual thermostat head up complete-
ly, loosen the fastening and pull the thermostat 
off of the valve. 
2.  Use an appropriate adapter, if required, 
and push it onto the valve.
3.   Screw the connector on the valve or the 
adapter. 
4.   Now, you put SPARmatic Zero on the 
connector until it noticeably clicks into place.
ATTENTION: It must be possible to insert SPAR-
matic Zero without applying force, ensure that the 
appliance is in the „
“ or „
“ position.
valve  – adapter – coupling ring
valve – coupling ring
 Additional information about the different adapters 
are provided on page 20 or at: 
www.eurotronic.org
13
Setting heating and economy 
times
With SPARmatic Zero it is possible to set 4 heating 
and 4 economy times per day – one for each day 
or one for a block of several days. 
TAG1 to TAG7 represent the weekdays from Mon-
day to Sunday. Additionally, the corresponding 
days are shown as abbreviation below the menu 
bar on the display. 
Block construction:
T1– 5 = same programme from Monday to Friday
T
  
 1– 6 = same programme from Monday to Satur-
day
T 1– 7 = same programme from Monday to Sunday
 
 For non-programmed days the factory preset 
remains active.
Setting of an individual programme:
Press 
MENU
. Select the menu item 
 with the 
Button   or  . Press 
OK
 for Monday is 
shown on the display. Select day/block with the 
Button   or  . Confi rm with 
OK
. Set the begin-
ning of the 1
st
 heating time (symbol  )with the But-
ton   or  . Confi rm with 
OK
. Set the beginning 
of the 1
st
 economy time (symbol  ) with the Button 
 or  . Confi rm with 
OK
.
10
    In case of a 
later installation, please switch 
in the menu to 
 
before you install the 
device. Herewith the installation is facilitated. 
Only mount it in this position. 
Dismounting 
 
   To remove SPARmatic Zero remove this at the  
, position, wait for a short period and then 
press on the unlocking device to detach the 
quick-release catch. Then pull the SPARmatic 
Zero from the valve.
pr
ess
14
Now, if desired, a 2
nd
, 3
rd
 or 4
th
 heating/economy 
time can be entered.  
➔ 
 If you do not want to set a further heating/
economy time confi rm „
“ with 
OK
.
The next day for programming is shown on the 
display.
➔ 
 If you do not want to enter a further day, leave 
the menu with 
MENU
. If the temperature is 
shown on the display the programming is 
fi nished.
➔ 
 Within the blocks you can also overwrite single 
days with differing times. 
Setting comfort and economy 
temperature
Press 
MENU
. Select the menu item 
 with the 
Button   or  . Confi rm with 
OK
. Set comfort 
temperature with the Button   or  . Confi rm 
with 
OK
. Set the economy temperature with the 
Button   or  . Confi rm with 
OK
.
Area 
: 8°C, freeze protection function is active
Area 
: valve is completely open
11
Adaptation
Initial installation: Press the button 
OK
 until 
 appears on the display so that SPARmatic 
Zero will be able to start its adaptation. The 
device will adapt itself to the stroke of your valve 
body. To do this the valve will now be opened and 
closed several times to store the end points. 
In some cases this process can take a few 
minutes. After successful adaptation it returns to 
normal mode. 
➔ 
 Should adaptation become necessary again, 
e.g. if your radiator does not cool down in the 
-Position, please press in the menu the 
button 
 until adaptation starts again.
➔ 
 If the mistake   is shown on the display place 
SPARmatic  Zero  onto  the  radiator  valve  and 
then take the batteries out for a short time in 
order to execute a reset. 
15
➔ 
By the way: Maximum energy saving can be   
 
obtained with an economy temperature which  
 
is about 5 ˚C below the comfort temperature.
 Manual operation
With the Button   or   an adaptation of the 
room temperature is possible at any time. In 
the AUTO-mode it remains active until the next 
switch point is reached. Now, the usual pro-
gramme becomes active again.
Further functions
Timer function
The timer function is selected with the timer-
button  
. With this function an user-defi ned 
temperature for a programmable period can 
be entered. This can be very useful in case of a 
party, for example. Press 
. First, the time for 
which the time programme has been deactivated 
is shown. Confi rm with 
OK
. Now, the desired 
temperature can be set. Confi rm with 
OK
.
12
Basic operating modes
MANU-mode
In the MANU-mode SPARmatic Zero adjusts to 
the manually specifi ed temperature.
AUTO-mode
In the AUTO-mode SPARmatic Zero changes 
between to temperatures according to the time 
programme that has been set:
 comfort temperature (factory preset 21°C)
   economy temperature (factory preset 16°C)
The heating and economy times can be specifi ed 
via the adjustable time programme. It is possible 
to set 8 switch points (4 heating and 4 economy 
times) per day at the most. SPARmatic Zero has 
the following factory preset:
Heating time:
Heating with comfort temperature
(factory preset: 1
st
 heating time at 07:00)
Economy time:
lowering to economy temperature
(factory preset: 1
st
 economy time at 22:00) 
16
Offset
If the perceived temperature signifi cantly differs 
from the set thermostat temperature a tempera-
ture set up can be executed. 
Press 
MENU
. Select the menu item 
 with the  
Button   or  . Confi rm with 
OK
. The degree 
setting 
 will fl ash on the display. Now, set 
up the desired adaptation for the temperature 
(from -5 up to +5°C) with the Button   or  . 
Confi rm your entry with 
OK
. The temperature 
display does not change! 
Window function
If you open a window and consequently the 
temperature drops signifi cantly, SPARmatic 
Zero will automatically close the heating valve 
in order to save energy. The display will show  
. Afterwards, SPARmatic Zero will resume 
normal operation. For the set up select 
 in 
the menu. Confi rm with 
OK
. First, the sensibil-
ity is selected with the  Button   or   (
 = 
high sensibility, 
 = medium sensibility (factory 
preset), 
 = low sensibility). Confi rm with 
OK
Now, you enter the time (10 min (factory preset) - 
60 min) for which the valve should remain closed. 
Confi rm with 
OK
.