Intel Desktop Board D915GEV/D915GRF Technical Product Specification
76
2.12 Thermal Considerations
CAUTION
A chassis with a maximum internal ambient temperature of 38 
o
C at the processor fan inlet is a 
requirement.  Use a processor heatsink that provides omni-directional airflow (as shown in 
Figure 24) to maintain required airflow across the processor voltage regulator area.
OM16996
 
Figure 24.  Processor Heatsink Airflow
CAUTION
Failure to ensure appropriate airflow may result in reduced performance of both the processor 
and/or voltage regulator or, in some instances, damage to the board.  For a list of chassis that 
have been tested with Intel desktop boards please refer to the following website:  
All responsibility for determining the adequacy of any thermal or system design remains solely 
with the reader.  Intel makes no warranties or representations that merely following the 
instructions presented in this document will result in a system with adequate thermal performance.
CAUTION
Ensure that the ambient temperature does not exceed the board’s maximum operating temperature.  
Failure to do so could cause components to exceed their maximum case temperature and 
malfunction.  For information about the maximum operating temperature, see the environmental 
specifications in Section 2.14.