MD 9035 Digital Multimeter Series
Safety
4
1 Safety
Terms in this manual
WARNING
identifies conditions and actions that could result in serious injury or even
death to the user.
death to the user.
CAUTION
identifies conditions and actions that could cause damage or malfunction
in the instrument.
in the instrument.
This manual contains information and warnings that must be followed for operating the
instrument safely and maintaining the instrument in a safe operating condition. If the
instrument is used in a manner not specified by the manufacturer, the protection
provided by the instrument may be impaired. The meter is intended only for indoor use.
The meter protection rating, against the users, is double insulation per IEC61010-1 2nd
Ed., EN61010-1 2nd Ed., UL61010-1 2nd Ed. and CAN/CSA C22.2 No. 61010.1-0.92 to
Category II 1000V AC & DC.
Terminals (to COM) measurement category:
V :
Category II 1000V AC & DC
A & mA
A : Category II 450V AC & DC
Per IEC61010-1 2nd Ed. (2001) Measurement Category
Measurement Category II (CAT II) is for measurements performed on circuits directly
connected to the low voltage installation. Examples are measurements on household
appliances, portable tools and similar equipment.
WARNING
To reduce the risk of fire or electric shock, do not expose this product to rain or
moisture. To avoid electrical shock hazard, observe the proper safety precautions when
working with voltages above 60 VDC or 30 VAC rms. These voltage levels pose a
potential shock hazard to the user. Do not touch test lead tips or the circuit being tested
while power is applied to the circuit being measured. Keep your fingers behind the
finger guards of the test leads during measurement. Inspect test leads, connectors, and
probes for damaged insulation or exposed metal before using the instrument. If any
defects are found, replace them immediately. Do not measure any current that exceeds
the current rating of the protection fuse. Do not attempt a current measurement to any
circuit where the open circuit voltage is above the protection fuse voltage rating.
Suspected open circuit voltage should be checked with voltage functions. Never attempt
a voltage measurement with the test lead inserted into the
A/mA or A input jack. Only
replace the blown fuse with the proper rating as specified in this manual.
CAUTION
Disconnect the test leads from the test points before changing functions. Always set the
instrument to the highest range and work downward for an unknown value when using
manual ranging mode.
CAUTION
Disconnect the test leads from the test points before changing functions. Always set the
instrument to the highest range and work downward for an unknown value when using
manual ranging mode.