To set the reference voltage, perform the following steps: 
1.  Press 
  + 
  for dB math operation and the present reference value is displayed: 
   R.F:+0.00000 
2.  Use 
  and 
  keys to choose a numerical place and use 
  and 
  keys to 
increment or decrement the digits. Enter a value and units prefix. 
3.  Press 
  (ENTER) to confirm the reference voltage, the message “SAVED” will be displayed for 
a moment. Then the meter will return back to the measurement status. 
4.  The display will now show result of the dB calculation. 
 
If you want to change the parameter values when dB function is in effect, you can do the following:
 
1.  Press 
  to enter the menu on the menu level, “A: MATH MEU” will be displayed. 
2.  Press 
  to move down to the command  level within the MATH MEU,  “4: dB REF  “will  be 
displayed. 
3.  Press 
  to enter the parameter level, and the present reference value will be displayed: 
R.F: +1.00000 .   
4.  Use 
  and 
  keys to choose a numerical place and use 
  and 
  keys to 
increment or decrement the digits. Enter a value and units prefix. 
5.  Press 
  (ENTER) to confirm the reference value, the message “SAVED” will be displayed for a 
moment, and the meter will return to the command level. Press 
  to cancel the reference value 
input, and the meter will return back to the command level without changing the reference value. 
6.  Press 
  → 
  key to exit the menu and return to the dB math operation status. 
 
Note: 
The dB calculation takes the absolute value of the ratio V
IN
/V
REF
.  The largest negative 
value of dB is -160 dB. This will accommodate a ratio of V
IN
 = 1 µV, V
REF
 = 1000 V. 
3.9.3    dBm Calculation 
dBm  is defined as decibels above or below a 1  mW reference. With user-programmable reference 
impedance, the meter reads 0 dBm when the voltage needed to dissipate 1 mW through the reference 
impedance is applied. The relationship between dBm, reference impedance, and the voltage is defined 
by the following equation: 
mW
Z
V
dBm
REF
IN
1
)
(
log
10
2
=
 
Where:   
IV
V
is the DC or AC input signal. 
REF
Z
is the specified reference impedance. 
If a relative value is in effect when dBm is selected, the value is converted to dBm then REL is applied to 