Peter Electronic VD 075/E2 1-phase frequency inverter, to , 2I000.23075 2I000.23075 Hoja De Datos
Los códigos de productos
2I000.23075
Appendix
Drive error code information in Register 6:
Drive Error Code
Drive Display Fault Code Description
0x00
stop
Drive healthy no fault
present When the drive is
disabled the display will
STOP. The display will
change if drive is running.
present When the drive is
disabled the display will
STOP. The display will
change if drive is running.
0x01
OI-b
Brake channel over current
0x02
OL-br
Brake resistor overload
0x03
O-I
Over current on drive
output. Excess load on the
motor. Over temperature
on the drive heatsink
output. Excess load on the
motor. Over temperature
on the drive heatsink
0x04
I. t-trP
Drive has tripped on
overload after delivering
>100% of value in P-08 for a
period of time.
overload after delivering
>100% of value in P-08 for a
period of time.
0x05
PS-Trp
Internal power stage fault
0x06
O.Uo1t
Over voltage on DC bus
0x07
U.Uo1t
Under voltage on DC bus
0x08
O-t
Heatsink over temperature
0x09
U-t
Under temperature
0x0A
P-def
Factory Default parameters
have been loaded
have been loaded
0X0B
E-triP
External trip (on digital
Input 3)
Input 3)
0X0C
SC-trP
Serial communications loss
trip
trip
0X0D
RESERVED
0X0E
P-LOSS
Input phase loss trip
0X0F
SPIN-F
Spin start failed
0x10
th-Flt
Faulty thermistor on
heatsink.
heatsink.
0X11
data-F
Internal memory fault.
0X12
4-20 F
Analog input current out of
range (4-20mA)
range (4-20mA)