Peter Electronic VD 075/E2 1-phase frequency inverter, to , 2I000.23075 2I000.23075 Hoja De Datos

Los códigos de productos
2I000.23075
Descargar
Página de 6
Appendix  
Drive error code information in Register 6:  
Drive Error Code  
Drive Display Fault Code   Description  
0x00  
stop  
Drive healthy no fault 
present When the drive is 
disabled the display will 
STOP. The display will 
change if drive is running.  
0x01  
OI-b  
Brake channel over current  
0x02  
OL-br  
Brake resistor overload  
0x03  
O-I   
Over current on drive 
output. Excess load on the 
motor. Over temperature 
on the drive heatsink  
0x04  
I. t-trP  
Drive has tripped on 
overload after delivering 
>100% of value in P-08 for a 
period of time.  
0x05  
PS-Trp  
Internal power stage fault  
0x06  
O.Uo1t  
Over voltage on DC bus  
0x07  
U.Uo1t  
Under voltage on DC bus  
0x08  
O-t  
Heatsink over temperature  
0x09  
U-t  
Under temperature  
0x0A  
P-def  
Factory Default parameters 
have been loaded  
0X0B  
E-triP  
External trip (on digital 
Input 3)  
0X0C  
SC-trP  
Serial communications loss 
trip  
0X0D  
  
RESERVED  
0X0E  
P-LOSS  
Input phase loss trip  
0X0F  
SPIN-F  
Spin start failed  
0x10  
th-Flt  
Faulty thermistor on 
heatsink.  
0X11  
data-F  
Internal memory fault.  
0X12  
4-20 F  
Analog input current out of 
range (4-20mA)