Whirlpool UXT4230AYW Manual De Propietario

Descargar
Página de 32
11
Make Electrical Connection
1. Disconnect power. 
2. Use UL listed wire connectors and connect white wires (A) 
together.
3. Use UL listed wire connectors and connect black wires (B) 
together.
4. Connect green (or bare) ground wire from power supply to 
green ground screw in terminal box and securely tighten.
5. Install terminal box cover.
6. Reconnect power.
Complete Installation
1. Install the 75W (max.) Incandescent light bulb. See 
“Replacing the Incandescent Light Bulb” in the “Range Hood 
Care” section.
2. Replace grease filter if removed. See the “Range Hood Care” 
section.
3. Check the operation of the range hood fan and light. See 
“Range Hood Use” section.
If range hood does not operate, check to see whether a 
circuit breaker has tripped or a household fuse has blown. 
Disconnect power and check wiring connections. 
NOTE: To get the most efficient use from your new range hood, 
read the “Range Hood Use” section.
RANGE HOOD USE
The range hood is designed to remove smoke, cooking vapors 
and odors from the cooktop area. For best results, start the hood 
before cooking and allow it to operate several minutes after the 
cooking is complete to clear all smoke and odors from the 
kitchen.
The hood controls are located on the front panel of the range 
hood.
Range Hood Controls
Operating the light
Turn the light switch to the right 1 position for Low (night light).
Turn the light switch to the right 2 positions for High.
Operating the fan
The fan is variable speed. Rotate the fan switch to the right to 
turn the fan to the ON position. Continue to rotate the switch to 
the desired fan speed.
To turn the fan OFF, rotate the fan speed switch to the left to the 
OFF position.
A. White wires
B. Black wires
C. UL listed wire connector
D. Green (or bare) ground wire
E. Home power supply cable or 
power cord accessory kit
F. UL listed or CSA approved 
½" strain relief
G. Green ground screw
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
B
C
D
E
F
G
WARNING
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in 
terminal box.
Failure to do so can result in death, fire, or 
electrical shock.
A. Incandescent light housing and cover
B. Grease filter retainer
C. Grease filter
A. Fan speed switch
B. On/Off light switch
A
C
B
A
B