Graco 308178H Dynamic Surge Suppressor Manual De Usuario

Descargar
Página de 18
8
308178
Troubleshooting
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 4.
Relieve the pressure.
Check all possible problems and causes before
disassembling the pump or surge suppressor.
PROBLEM
CAUSE
SOLUTION
Surge suppressor operates 
erratically
Clogged air line or air inlet
Inspect; clear.
Air line connected to pressure gauge
port
Connect air line to air inlet
(see page 11).
Clogged fluid supply line, fluid inlet or
fluid outlet
Inspect; clear.
Diaphragm (13 or 21
[
) ruptured
Replace. See page 9.
Unbalanced air pressures between
pump and surge suppressor
Ratio of air inlet pressure to surge
suppressor and air inlet pressure to
pump must be the same as pump ra-
tio, but air pressure to surge sup-
pressor must never exceed 100 psi
(0.7 MPa, 7 bar). See page 7.
Air bubbles in fluid
Fluid supply line loose
Tighten.
Diaphragm (13 or 21
[
) ruptured
Replace.  See page 9.
Manifold o-rings (16) leaking
Replace.  See page 10.
Fluid in exhaust air
Diaphragm (13 or 21
[
) ruptured
Replace.  See page 9.
Diaphragm plates (12 or 32) loose or
damaged
Tighten or replace.  See page 9.
Damaged shaft (11) or shaft o-rings
(19)
Replace.  See page 9.
Pump leaks air or fluid from cover (7)
V-clamp (6) is loose
Tighten V-clamp.  See page 9.
[
 Ref. No. 21, the PTFE diaphragm, is used only in Surge Suppressor Models 224892 and 224894.