Graco Trabon LC-1000 Manual De Usuario

Descargar
Página de 8
The Trabon microprocessor based LC-1000 Controller 
is a multi-use solid state controller that is dedicated to 
the operation and monitoring of intermittent operat-
ing series and parallel centralized lubrication systems 
equipped with a cycle or pressure switch for cycle 
completion feed back.
The LC-1000 monitors and schedules lubrication inter-
vals in either time or stroke/cycle basis in values rang-
ing from 1 to 9999.  Pump may be self cycling or single 
cycle type requiring a pulsed output.
Four units are available for 12 VDC, 24 VDC, 115 
VAC, or 230 VAC operation.  The LC-1000 is easy to 
program in the fi eld using four mini push-buttons.  The 
programming requires no special knowledge or training 
of computer language.  During power down or outage, 
all data is saved in EEPROM (Electrically Erasable Pro-
gramming Read Only Memory).  As power is restored, 
counting and pump status are restored to values prior 
to the loss of power.  
SPECIFICATIONS
Power Supply
115  VAC + 10%, 50/60 Hz, 1 ph
230  VAC + 10%, 50/60 Hz, 1 ph
  12  VDC + 10%
  24  VDC + 10%
Output Loading
Main Pump Load:  ..........12 VDC – 230 VAC, 50/60 Hz
      10 Amp Relay Output (External Fused by User)
Fault Output Signal: ........12 VDC – 230 VAC, 50/60 Hz
  1 Amp Resistive Max. (N.O.) Dry Isolated Contact 
  (External Fused by User)
Temperature Range
  Do Not Locate unit in Direct Sunlight
  Operating::  -20
O
C to 50
O
C (-4
O
F to 122
O
F)
  Storage:  -25
O
C to 60
O
C (-13
O
F to 140
O
F)
Enclosure
Plastic with Clear Cover, NEMA 4X, IP 66
Display
Supertwist LCD
Annotated 4 Digit
4 LED’s:  PWR (GN), LUBE (YW), FAULT (RD), 
CYCLE (YW)  
Stroke Input 
Maximum Input Rate:  10 hz (600 CPM)
Nominal 12 Volts for 12 VDC Version
Nominal 24 Volts for 24 VDC, 115 VAC, 230 VAC 
Versions
Selectable for either Source or Sink Solid State 
Proximity Switch or Dry Contact 10 mA Max.
Other Inputs
Cycle Switch: ........12 Volts, Dry Contact, 2.5 mA Max.
         Counts 
Half 
Cycles       
Programming Selection
Output ON: ...................... 1 to 9999 Seconds, Minutes, 
            Hours, 
Counts
Output OFF:..................... 1 to 9999 Seconds, Minutes, 
            Hours, 
Counts 
Cycle Counter:  .............................Half Counts (0 to 99)
Pump: ....................................... Steady State or Pulsed
          Pulse Off Time (Prime) – 3 Seconds Fixed
          Pulse On Programmable - 0 to 99 Seconds
(Pre-Lube function is not available)
Program Entry
4 Mini Push Buttons – Program, Increase, Shift, Enter
EEPROM 
Electrically Erasable Programming Read Only Memory
LC-1000 Lube System Controller