Process I/O
ET 200S distributed I/O
Digital electronics modules
11/46
Siemens ST PCS 7 · November 2007
11
B) Subject to export regulations: AL: N, ECCN: EAR99H
Selection and Ordering Data
Order No.
Digital inputs for floating contacts
 
DI 2 x 24 V DC, standard
Ordering unit 5 items
6ES7 131-4BB01-0AA0
B)
DI 4 x 24 V DC, standard
Ordering unit 5 items
6ES7 131-4BD01-0AA0
B)
DI 2 x 24 V DC, High Feature; 
with diagnostics
• Short-circuit monitoring
Ordering unit 5 items
6ES7 131-4BB01-0AB0
B)
DI 4 x 24 V DC, High Feature; 
with diagnostics
• Short-circuit monitoring
Ordering unit 5 items
6ES7 131-4BD01-0AB0
DI 4 x 24 to 48 V AC/DC, High 
Feature; with diagnostics
• Wire break monitoring (external 
resistance circuit required)
• Monitoring of the fuse
• Monitoring of the load voltage
Ordering unit 5 items
6ES7 131-4CD00-0AB0
B)
DI 4 x 24 V DC, NAMUR
Ordering unit 1 item
6ES7 131-4RD00-0AB0
B)
DI 2 x 120 V AC, standard
Ordering unit 5 items
6ES7 131-4EB00-0AB0
B)
DI 2 x 230 V AC, standard
Ordering unit 5 items
6ES7 131-4FB00-0AB0
B)
Failsafe digital input
 
4/8 F-DI 24 V DC PROFIsafe 
8 DI safety-related SIL 2 or 4 DI 
safety-related SIL 3, with diagnos-
tics
• Cyclic short-circuit test
• Discrepancy monitoring of 
2 channels for SIL 3 (adjustable 
discrepancy time)
• Safe monitoring of communica-
tion with PROFIsafe
Ordering unit 1 item
6ES7 138-4FA03-0AB0
B)
Digital outputs for DC voltage (suitable for solenoid valves, 
DC contactors, indicator lights etc.)
 
DO 2 x 24 V DC/0.5 A, standard
Ordering unit 5 items
6ES7 132-4BB01-0AA0
B)
DO 2 x 24 V DC/2 A, standard
Ordering unit 5 items
6ES7 132-4BB31-0AA0
DO 2 x 24 V DC/0.5 A, High 
Feature, with diagnostics
• Connection of a default value by 
channel in the event of CPU fail-
ure (parameterizable)
• Short-circuit monitoring by 
channel
• Broken wire monitoring by chan-
nel (when "1" signal)
Ordering unit 5 items
6ES7 132-4BB01-0AB0
B)
DO 2 x 24 V DC/2 A, High Fea-
ture, with diagnostics
• Connection of a default value by 
channel in the event of CPU fail-
ure (parameterizable)
• Short-circuit monitoring by 
channel
• Broken wire monitoring by chan-
nel (when "1" signal)
Ordering unit 5 items
6ES7 132-4BB31-0AB0
B)
DO 4 x 24 V DC/0.5 A, standard
Ordering unit 5 items
6ES7 132-4BD01-0AA0
DO 4 x 24 V DC/2 A, standard
Ordering unit 5 items
6ES7 132-4BD32-0AA0
B)
Digital output for AC voltage (suitable for solenoid valves, 
AC contactors, indicator lights etc.)
 
DO 2 x 24 to 230 V AC, 2 A
• Connection of a default value by 
channel in the event of CPU fail-
ure (parameterizable)
Ordering unit 5 items
6ES7 132-4FB01-0AB0
B)
Relay output (suitable for solenoid valves, contactors, motor 
starters, miniature motors and indicator lights)
 
2 x RO, NO contact
24 to 120 V DC/5 A
24 to 230 V AC/5 A
• Connection of a default value by 
channel in the event of CPU fail-
ure (parameterizable)
Ordering unit 5 items
6ES7 132-4HB01-0AB0
2 x RO, changeover contact
24 to 48 V DC/5 A
24 to 230 V AC/5 A
• Connection of a default value by 
channel in the event of CPU fail-
ure (parameterizable)
Ordering unit 5 items
6ES7 132-4HB10-0AB0
B)
Failsafe digital output
 
4 F-DO 24 V DC/2 A PROFIsafe
Safety-related up to SIL 3, with 
diagnostics, switching to low/high
• Short-circuit monitoring by 
channel
• Overload monitoring by channel
• Broken wire monitoring by chan-
nel (when "1" signal)
• Safe monitoring of communica-
tion with PROFIsafe
• Diagnostics inside module
Ordering unit 1 item
6ES7 138-4FB02-0AB0
B)
Accessories
 
Reserve modules for ET 200S
for reserving unused slots for any 
electronics module
• 15 mm wide (Ordering unit 
5 items)
6ES7 138-4AA01-0AA0
B)
• 30 mm wide (Ordering unit 
1 item)
6ES7 138-4AA11-0AA0
B)
For further accessories, e.g. for 
labeling, see Catalog IK PI
Selection and Ordering Data
Order No.
© Siemens AG 2007