 ELECTRICAL CONNECTIONS 
4
35
SITRANS FX300
www.siemens.com/flow
06/2009 - SFIDK.PS.050.F2.02   A5E02100423
The pulse output is a passive "open collector" output which is electrically separated from the 
current interface and the measuring sensor. It can be configured as a high current output or 
NAMUR output using a jumper on the amplifier board.
The maximum frequency of the pulse output is f
max
 = 0.5 Hz
The maximum frequency of the pulse output is f
max
 = 0.5 Hz
Jumper in NAMUR setting
Jumper in NAMUR setting
Jumper in NAMUR setting
Jumper in NAMUR setting
R
i
 = 900 Ω
U
max
 = 36 VDC
Jumper in high current setting
Jumper in high current setting
Jumper in high current setting
Jumper in high current setting
Open:
Maximum voltage U
max
 = 36 VDC
Closed current I
R
 < 1 mA
Closed:
Maximum current I
max
 = 100 mA
Voltage U < 2 VDC
Figure 4-4: Jumper settings pulse output
1  Electronic insert
2  Jumper on board
3  Jumper in high current setting
4  Jumper in NAMUR setting