8.25 AT^SNFS Select audio hardware set
Test command
AT^SNFS=?
Response
^SNFS: (list of supported
<audMode>s) OK
Parameter
See write command
Read command
AT^SNFS?
Response
^SNFS: <audMode> OK
Parameter
See write command
Write command
AT^SNFS=
<audMode>
<audMode>
The write command serves to set the audio mode required for the connected
equipment. Please note that the selected mode is not saved to the non-volatile
store and needs to be restored manually, if the GSM engine was powered down.
equipment. Please note that the selected mode is not saved to the non-volatile
store and needs to be restored manually, if the GSM engine was powered down.
Response
OK
If error is related to ME functionality:
+ CME ERROR: <error>
If error is related to ME functionality:
+ CME ERROR: <error>
Parameters
<audMode> 1
Audio mode 1: Standard mode optimized for the default handset,
that can be connected to the analog interface 1 (see your
"Hardware Interface Description" for information on this hand-
set.) To adjust the volume use the knob of the default handset.
This handset can be used in audio mode 4 with user defined pa-
rameters.
Note: The default parameters are determined for type approval
and are not adjustable with AT commands.
that can be connected to the analog interface 1 (see your
"Hardware Interface Description" for information on this hand-
set.) To adjust the volume use the knob of the default handset.
This handset can be used in audio mode 4 with user defined pa-
rameters.
Note: The default parameters are determined for type approval
and are not adjustable with AT commands.
2
Audio mode 2: Customer specific mode for a basic handsfree
device (Siemens Car Kit Portable) connected to the analog in-
terface 2. Audio parameters can be adjusted with AT commands
device (Siemens Car Kit Portable) connected to the analog in-
terface 2. Audio parameters can be adjusted with AT commands
3
Audio mode 3: Customer specific mode for a mono-headset that
connects to the analog interface 2. Audio parameters can be
adjusted with AT commands.
connects to the analog interface 2. Audio parameters can be
adjusted with AT commands.
4
Audio mode 4: Customer specific mode for a user handset that
connects to the analog interface 1. Audio parameters can be
adjusted with AT commands.
connects to the analog interface 1. Audio parameters can be
adjusted with AT commands.
5
Audio mode 5: Customer specific mode intended for the analog
interface 1. Audio parameters can be adjusted with AT com-
mands.
interface 1. Audio parameters can be adjusted with AT com-
mands.
6
Audio mode 6: Customer specific mode intended for the analog
interface 2. Audio parameters can be adjusted with AT com-
mands.
interface 2. Audio parameters can be adjusted with AT com-
mands.
Reference
Siemens
Note