Philips Lighting Indoor Furnishings TL5 Manual De Usuario

Descargar
Página de 27
13
2000-11-07
Lamp
Discharge
Lamp
Lamp
Luminous
Luminous
type
current
voltage
power
flux
efficacy
mA
V
W
lm
lm/W
‘TL’5 HO 24W
270
78
21
1830
87
300
75
22,5
1950
87
435
70
30
2410
80
‘TL’5 HO 39W
270
119
32
3020
94
340
112
38
3500
92
435
106
46
3970
86
‘TL’5 HO 54W
370
125
46
4400
96
455
118
53,8
5000
93
625
110
68
5900
87
‘TL’5 HO 49W
180
209
38
3970
104
255
191
49,3
4930
100
295
184
55
5370
98
‘TL’5 HO 80W
295
188
55
5370
98
555
145
80
7000
88
600
142
85
7330
86
In the following table the dependency on the discharge current is given at top of the lumen curve.
Luminous flux and efficacy in the table below are only applicable for colours /827, /830 and /840. For other colours these values are in line
with the preceding table.
Note: 1) Data after 100 operating hours.
2) A discharge current less than the lowest value given for each lamp type will have a negative effect on lamp life unless extra electrode 
heating is used to keep the electrode at a sufficiently high temperature.
3) A discharge current of more than the highest value given for each lamp type will have a negative effect on lamp life.
4) The bold printed values correspond with the nominal lighting characteristics
5) Data at 35 ºC ambient temperature.