Philips Lighting Indoor Furnishings TL5 Manual De Usuario

Descargar
Página de 27
For ‘TL’5 HO 54W:
Note: Also the requirement I
LL
max.=490 mA should be met.
For ‘TL’5 HO 49W:
Note: Also the requirement I
LL
max.=240 mA should be met.
20
2000-11-07
Figure 4.2.5: “target setting” curve ‘TL’5 HO 54W
I
D
I
LL
I
LH
Normal operation
370 - 625 mA
< 525 mA
370 - 650 mA
Dimming operation
50 - 450 mA
< 525 mA
450 - 650 mA
I
D
I
LL
I
LH
Normal operation
180 - 320 mA
< 270 mA
180 - 330 mA
Dimming operation
25 - 180 mA
< 270 mA
230 - 330 mA
Figure 4.2.6: “target setting” curve ‘TL’5 HO 49W
to be
published
to be
published
For ‘TL’5 HO 80W:
Note: Also the requirement I
LL
max.=240 mA should be met.
Regarding the figures and the preceding tables the following
remarks should be made:
1) The actual data given in this Product Information brochure is
also the subject of discussion in a working group of ELMAPS
(European Lamp Manufacturers Association for the Preparing of
Standards).This will result in due time in new data in the rele-
vant IEC standards.Therefore the data given here should be
considered as preliminary.
2) If the lamp current (I
D
) is varied between the limits given at
normal operation, additional heating is optional, but not strictly
required.
3) In addition to the relation between the lamp current and the
Lead-High current, the Lead-Low current (I
LL
) may have any
value < I
LL
max.The maximum allowed values for the Lead-Low
current are given in the tables. Lead-Low currents > I
LL
max.
will cause accelerated end-blackening.
4) It will be clear that practical lamp - ballast combinations will
have settings deviating from the ideal “target setting” curve.
The grey area in the graph indicates the “acceptable” range of
deviation. It is difficult to indicate quantitatively the effects on
lamp life for settings deviating from the “target setting”.
It is generally observed that higher values of the Lead High 
current (I
LH
) lead to strong end-blackening. If the Lead-High 
current is below the “target setting” the electrode becomes too
cold and sputtering of the emitter may occur. If the Lead High
current is reduced below the grey area, a short life of the lamp
will occur.
Figure 4.2.7: “target setting” curve ‘TL’5 HO 80W
to be
published
I
D
I
LL
I
LH
Normal operation
440 - 715 mA
< 575 mA
440 - 770 mA
Dimming operation
55 - 440 mA
< 575 mA
480 - 770 mA