Orbit Manufacturing ORBIT 2000 Manual De Usuario

Descargar
Página de 139
Page 8 - 2
Maintenance
 © GBC Films Group January 2001
Orbit™ 2000 Operation and Maintenance  Manual
8.1  Maintenance schedule
It is necessary to lubricate and inspect individual parts at regular intervals to prolong the life and
ensure the correct functioning of the machine. Safety as described in Section 1 of this manual must be
followed when performing any type of maintenance.
DAILY
– Check the quantity of condensed water in the air treatment unit.
  If the amount in the vessel is higher than 20 mm, release the fluid.
– Check the presence of covers and bolts
– Check the correct function of sensors
– end switches of the feeding table
– capacity sensor
– sensor protecting the feeding head
– control sensors of removable covers
– emergency stop push button
– Cleaning of the rollers and machine.
EVERY TWO WEEKS
– Lubricate and grease with oil or spray all sliders and leading spindles
– Clean the cam and grease
– Clean and grease guiding rollers